Article Text
Abstract
Background Marfan syndrome (MFS) commonly leads to progressive aortic dilation, aneurysm formation and aortic dissection, particularly at the aortic sinuses (∼60% of dissections), and descending thoracic aorta (∼30% of dissections). Abnormal aortic blood flow patterns may contribute to the enlargement and dissection of an inherently weak aorta, or to late complications after aortic dissection.
Methods 18 patients with MFS (3 with a prior history of aortic dissection and aortic root surgery, 15 with no such history) and 18 healthy volunteers matched for age, sex and height underwent CMR at 3T, using a time-resolved 3-dimensional flow technique. The aorta was segmented into regions on the basis of anatomic features (Abstract 108 figure 1A). Each segment was visualised using streamlines (Abstract 108 figure 1B) and particle traces, and was rated as normal or abnormal, (defined as the presence of turbulent flow vortices) and, where abnormal, extent of abnormality was classified on a 4-point scale determined by the extent of radial involvement of the aortic lumen. Wall shear stress (WSS) quantification was undertaken at predefined aortic locations (Abstract 108 figure 1A).
Results Significant vortical flow in any segment (defined as flow disturbance occupying more than one half of the aortic lumen) was present in all patients with MFS, but in only 7/18 controls (p<0.0005). The severity of flow disturbance was greater in MFS patients than controls (median severity score 3 for Marfan patients, 1 for controls, p<0.0005). There was marked regional variation in the prevalence of major flow disturbance (Abstract 108 figure 2), with the sinuses of Valsalva and proximal descending aorta being most frequently affected. Prior repaired aortic dissection was associated with marked abnormalities of blood flow (Abstract 108 figure 1C), with corresponding increases in axial WSS within the true lumen of the dissected aorta (typical axial WSS in the dissected ascending aorta was +0.9 N/m2, compared to +0.54 N/m2 in healthy controls). Aortic flow disturbance in MFS was of one of three types: Type A: flow disturbance confined to the sinuses of Valsalva, Type B: flow disturbance confined to the proximal descending aorta, Type C: flow disturbance in both the sinuses of Valsalva and the proximal descending aorta.
Conclusion Patients with MFS commonly show aortic flow disturbance. The sinuses of Valsalva and proximal descending aorta are most frequently affected. Flow disturbance can be categorised into one of three categories, and we anticipate that flow abnormalities within a segment will predict progressive aortic dilation and dissection in an ongoing follow-up study.
- Marfan
- cardiac magnetic resonance
- aorta