Article Text

Download PDFPDF

Interventional cardiology
Clinical study of utilisation of thrombus aspiration catheters in patients with recovering from acute myocardial infarction underwent elective percutaneous
Free
  1. Li Wei1,
  2. Wu Li-Rong1,
  3. Lu Ming-Yu2,
  4. Wang Wei-Min2,
  5. Liu Jian2,
  6. Ma Yu-Liang2
  1. 1Cardiovascular Division, Guiyang Medical College Affiliated Hospital, Guiyang, China
  2. 2Peking University Peoples Hospital, Beijing, China

Abstract

Objective To observe the safety and efficiency of utilisation of ZEEK thrombus aspiration catheters in patients who recovering from acute myocardial infarction (AMI) underwent elective percutaneous coronary intervention (PCI).

Methods From July 2007 to December 2009, 61 patients with recovering from AMI (41 males, mean age of 59.27±10.56 years) were randomly received utilisation of ZEEK thrombus aspiration catheter (aspiration group, n=31) or routine PCI (non-aspiration group, n=30). Clinical and angiographic features between the two groups were analysed.

Results Baseline clinical features were similar between the two groups. TIMI 3 flow rate (93.55% vs 56.67%, p=0.001) immediately after PCI was significantly higher in aspiration group than that in non-aspiration group. Slow flow (TIMI 2 flow) rate (6.45% vs 26.66%, p=0.013), no-reflow (TIMI 0–1flow) rate (0 vs 16.67%, p=0.024), and corrected TIMI frames (27.94–5.80 vs 39.20±5.33, p=0.000) immediately after PCI were significantly lower in aspiration group than that in non-aspiration group. Left ventricular ejection fraction (LVEF) ((56.48±9.77)% vs 47.10±9.24)%, p=0.000), the rate of E peak/A peak<1 (16.13% vs 46.67%, p=0.017) and left ventricular end-diastolic diameter (LVEDD) (cm) (5.05±0.39 vs 5.92±0.47, p=0.000) at 1 week after PCI were statistically significant between the two groups. However, during early follow-up, there were no major adverse cardiac events (MACE) in the two groups.

Conclusions Utilisation of ZEEK thrombus aspiration catheters in patients with recovering from AMI is safe and effective, the thrombus aspiration catheters can effectively remove coronary thrombus, improve myocardial tissue perfusion, and can improve postoperative cardiac function, without increasing major adverse cardiac events.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.