Reproducibility of echocardiographic estimates of left ventricular dimensions.
  1. M A Stefadouros,
  2. M I Canedo

    Abstract

    Although echocardiography is ideally suited for repetitive use on a patient for evaluation of left ventricular function, the value of this application is minimised by the uncertainty as to whether changes in left ventricular dimensions observed on a patient at different times or by different observers are real or result from the ultrasonic beam penetrating the left ventricle at different angles. Accordingly, an instrument was designed and constructed in our laboratory to improve the reproducibility of echocardiographic measurements of left ventricular dimensions. The instrument represents an orthogonal reference frame by means of which the spatial orientation of the ultrasonic beam relative to the chest is determined and reproduced in subsequent studies, while the point of entrance of the beam is marked on the chest wall. Using this instrument, left ventricular echograms were initially recorded on a group (I) of 23 subjects with or without heart disease and the study was repeated 8 hours to 49 (mean 7) days later by the same observer and also, in 16 cases, by an independent observer. The average values from 2 to 6 (mean 4) heart cycles were used for the left ventricular end-diastolic dimension (Dd), end-systolic (Ds) dimension, and their difference (delta D). Differences in all three variables between studies were random and statistically insignificant, never exceeding 3-5 mm for Dd or Ds, and 4 mm for deltaD. For comparison, left ventricular internal dimensions were also obtained in a seprate group (II) of 14 subjects by the standard method of using the mitral valve as an internal landmark, without the benefit of this instrument. All 14 subjects had the initial study repeated within 8 hours to 11 (mean 3-8) days later by the same and also by an independent observer. Though in the group as a whole there was no significant difference in left ventricular dimensions between studies, individual variations reached 11 mm for Dd, 9 mm for Ds, and 9 mm for deltaD, and the degree of scatter was significantly larger than in group I. This initial experience indicates that the use of this instrument improves the reproducibility and enhances the reliability of estimates of echocardiographic left ventricular dimensions and function on a patient examined at different times by the same or independent observers.

    Statistics from Altmetric.com

    Request Permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.