TY - JOUR T1 - Optimal pacing modes after cardiac transplantation: is synchronisation of recipient and donor atria beneficial? JF - British Heart Journal JO - Heart SP - 195 LP - 198 DO - 10.1136/hrt.68.8.195 VL - 68 IS - 8 AU - Gareth Parry AU - Katie Malbut AU - John H Dark AU - Rodney S Bexton Y1 - 1992/08/01 UR - http://heart.bmj.com/content/68/8/195.abstract N2 - Objective—To investigate the response of the transplanted heart to different pacing modes and to synchronisation of the recipient and donor atria in terms of cardiac output at rest.Design—Doppler derived cardiac output measurements at three pacing rates (90/min, 110/min and 130/min) in five pacing modes: right ventricular pacing, donor atrial pacing, recipient-donor synchronous pacing, donor atrial-ventricular sequential pacing, and synchronous recipient-donor atrial-ventricular sequential pacing.Patients—11 healthy cardiac transplant recipients with three pairs of epicardial leads inserted at transplantation.Results—Donor atrial pacing (+11% overall) and donor atrial-ventricular sequential pacing (+8% overall) were significantly better than right ventricular pacing (p < 0·001) at all pacing rates. Synchronised pacing of recipient and donor atrial segments did not confer additional benefit in either atrial or atrial-ventricular sequential modes of pacing in terms of cardiac output at rest at these fixed rates.Conclusions—Atrial pacing or atrial-ventricular sequential pacing appear to be appropriate modes in cardiac transplant recipients. Synchronisation of recipient and donor atrial segments in this study produced no additional benefit. Chronotropic competence in these patients may, however, result in improved exercise capacity and deserves further investigation. ER -