Table 2

Diagnostic value of NT-proBNP in detecting left ventricular systolic dysfunction

LVEF cut offSensitivity/specificityPPV/NPVAUCNT-proBNP (pmol/l)*Diagnoses made per 100 screenedDiagnoses missed per 100 screenedFalse positives per 100 screened
AUC, area under the curve; LVEF, left ventricular ejection fraction; NPV, negative predictive value; PPV, positive predictive value.
*NT-proBNP concentration corresponding to optimal combination of sensitivity and specificity.
50% (n = 77)0.70/0.630.20/0.940.7041.58.023.4432.8
45% (n = 58)0.74/0.640.16/0.960.7343.36.392.2432.9
40% (n = 38)0.76/0.670.12/0.980.7948.94.301.3631.1
35% (n = 21)0.76/0.850.14/0.990.83100.52.380.7514.5