Table 4

Predictive accuracy of echocardiographic parameters of stenosis severity for aortic valve events

c-statistics
AUC95% CIp Value*SensitivitySpecificity
MPG0.680.63 to 0.73<0.00162.666.5
Jet velocity0.670.62 to 0.72<0.00158.868.3
AVA0.560.51 to 0.6246.070.5
AVAindex0.590.53 to 0.640.1551.267.9
VR0.620.57 to 0.670.0684.437.9
VR-adjusted AVA0.620.57 to 0.670.0277.345.1
VR-adjusted MPG0.690.64 to 0.74<0.00164.068.3
SVI (VTI)†0.480.42 to 0.53<0.001 
SVI (Teichholz)†0.490.43 to 0.54<0.001 
  • Predictive accuracy of echocardiographic parameters of stenosis severity for aortic valve events in 435 patients with low gradient severe aortic stenosis. The area under the receiver operating characteristic curve (AUC) and the 95% CIs are shown for the unadjusted echocardiographic parameters, for VR-adjusted MPG and VR-adjusted AVA, and for stroke volume index derived from velocity time integral (VTI) and from the Teichholz formula.

  • *p Value vs AVA.

  • †No meaningful values for maximum sensitivity or specificity could be derived for SVI.