Table 5

Multivariable logistic and ROC analyses of multiple imaging parameters for predicting ventricular arrhythmia inducibility

ParameterMultivariable analysisROC analysis
OR (95% CI)p ValueR2AUC (95% CI)p Value
Model 1
 Hyperaemic MBF (per 0.1 mL/min/g)0.80 (0.67 to 0.96)0.020.280.76 (0.62 to 0.89)0.003
 Scar size (%)1.06 (0.98 to 1.15)0.14
Model 2
 Hyperaemic MBF (per 0.1 mL/min/g)0.80 (0.67 to 0.96)0.020.270.76 (0.63 to 0.90)0.002
 Scar size (g)1.05 (0.98 to 1.13)0.17
Model 3
 Hyperaemic MBF (per 0.1 mL/min/g)0.78 (0.65 to 0.94)0.0090.310.78 (0.65 to 0.91)0.001
 Perfusion defect (%)1.05 (0.99 to 1.12)0.13
Model 4
 Hyperaemic MBF (per 0.1 mL/min/g)0.79 (0.66 to 0.95)0.010.310.78 (0.65 to 0.91)0.001
 Innervation defect (%)1.06 (1.00 to 1.13)0.07
  • AUC, area under the curve; MBF, myocardial blood flow; ROC, receiver operating characteristic curve.