Table 6

Relation between change in ejection fraction on follow up after aortic valve replacement and contractile reserve at baseline

ΔEF on F/U CR+ CR−
Improved133
Worse010
χ2 = 15.2 (p = 0.0001)
  • CR+, positive contractile reserve; CR−, negative contractile reserve; ΔEF on F/U, change in ejection fraction on follow up.