Table 1

Performance of grey scale, colour coded, and power Doppler contrast echo techniques for detecting SPECT defects

Grey scale Colour coded Power Doppler p Value,
GS v C
p Value,
GS v P
p Value,
C v P
Predicting severe SPECT defects by severe myocardial contrast echo defects (score 0)
Sensitivity27%19%31%NSNSNS
Specificity75%78%83%NS< 0.01NS
Accuracy70%72%78%NS< 0.01NS
Predicting severe SPECT defects (score 0) by any contrast defect (score 0, 1)
Sensitivity38%27%46%NSNS< 0.05
Specificity42%47%54%NSNSNS
Accuracy41%46%53%NS< 0.05NS
Predicting any SPECT defect (score 0, 1) by any MCE defect
Sensitivity47%40%56%NSNS< 0.05
Specificity42%48%56%NSNSNS
Accuracy43%47%56%NS< 0.05NS
  • GS, grey scale; C, colour coded; P, power Doppler; MCE, myocardial contrast echo; SPECT, single photon emission computed tomography.