Skip to main content
Log in

Technetium-99m sestamibi and tetrofosmin myocardial single-photon emission tomography: Can we use the same reference data base?

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

The aim of this study was to compare technetium-99m labelled tetrofosmin and sestamibi myocardial perfusion single-photon emission tomography (SPET) with one common sestamibi reference file for bull's eye imaging, with quantitation of the extent and severity of perfusion defects. Twenty patients suspected or known to have coronary artery disease participated in the study. Patients first underwent routine sestamibi myocardial SPET over 2 days, receiving doses of 400–600 MBq at stress and 600–800 MBq at rest. Then within the same week a 1-day tetrofosmin myocardial SPET study was performed, with a dose of 300 MBq at stress, followed 2.5 h later by a dose of 750 MBq at rest. Bull's eye images were generated for visual evaluation. Black-out defects according to the Cequal software analysis were only recorded if they comprised more than 10 pixels in men and 20 in women. According to the Cequal program, extent score and severity scores were expressed as number of pixels and deviations below reference limits. Five patients had normal myocardial SPET imaging with both radiotracers, while 15 had reversible, irreversible or partially reversible defects. The concordance of the results was high. The only two significant differences were that one patient had a reversible defect which appeared to be located in different myocardial regions (LAD vs RCA), and another patient had a defect that was partially reversible with sestamibi but irreversible with tetrofosmin. The results showed very high correlation coefficients for the extent and severity scores (linear correlation coefficient values of 0.99 and 0.94, respectively). In conclusion, it appears that changing between sestamibi and tetrofosmin has little influence on the interpretation of bull's eye images from the data file of a common reference population using one of the tracers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sinusas AJ, Beller GB, Smith WH, Vinson EL, Brookeman V, Watson DD. Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: comparison of uptake patterns with thallium-201.J Nucl Med 1989; 30: 1456–1463.

    Google Scholar 

  2. Carvalho PA, Chiu ML, Kronauge JF. Subcellular distribution and analysis of technetium-99m-MIBI in isolated perfused rat hearts.J Nucl Med 1992; 33: 1516–1521.

    Google Scholar 

  3. Crane P, Laliberté R, Heminway S, Thoolen M, Orlandi C. Effect of mitochondrial viability and metabolism on technetium-99m-sestamibi myocardial retention.Eur J Nucl Med 1993; 20: 20–25.

    Google Scholar 

  4. Younés A, Songadele JA, Maublant J, Platts E, Pickett R, Veyre A. Mechanism of uptake of technetium-tetrofosmin. II. Uptake into isolated adult rat heart mitochondria.J Nucl Cardiol 1995; 2: 327–333.

    Google Scholar 

  5. Van Train KF, Arreda J, Garcia EV, et al. Quantitative sameday rest-stress technetium-99m sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality.J Nucl Med 1993; 34: 1494–1502.

    Google Scholar 

  6. Braat SH, Leclercq B, Itti R, Lahiri A, Sridhara B, Rigo P. Myocardial imaging with technetium-99m-tetrofosmin: comparison of one-day and two-day protocols.J Nucl Med 1994; 35: 1581–1585.

    Google Scholar 

  7. Yong TKA, Chambers J, Maisey MN, Fogelman I, Clarke SEM. Technetium-99m tetrofosmin myocardial perfusion scan: comparison of 1-day and 2-day protocols.Eur J Nucl Med 1996; 23: 320–325.

    Google Scholar 

  8. Flamen P, Bossuyt A, Franken PR. Technetium-99m-tetrofosmin in dipyridamole-stress myocardial SPECT imaging: intraindividual comparison with technetium-99m-sestamibi.J Nucl Med 1995; 36: 2009–2015.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Widding, A., Hesse, B. & Gadsbøll, N. Technetium-99m sestamibi and tetrofosmin myocardial single-photon emission tomography: Can we use the same reference data base?. Eur J Nucl Med 24, 42–45 (1997). https://doi.org/10.1007/BF01728307

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01728307

Key words

Navigation