Skip to main content
Log in

Prognostic value of computed tomography coronary angiography in patients with suspected coronary artery disease: a 24-month follow-up study

  • Cardiac
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

The aim of this study was to determine the predictive value of 64-slice computed tomography coronary angiography (CTCA) for major cardiac events in patients with suspected coronary artery disease (CAD). A total of 187 consecutive patients (119 men, age 62.5 ± 10.5 years) without known heart disease underwent single-source 64-slice CTCA (Somatom Sensation 64, Siemens) for clinical suspicion of CAD. Patients underwent follow-up for the occurrence of cardiac death, nonfatal myocardial infarction, unstable angina and cardiac revascularization. In total, 2,822 coronary segments were assessed. Forty-two segments (1.5%) were not assessable because of insufficient image quality. Overall, CTCA revealed absence of CAD in 65 (34.7%) patients, nonobstructive CAD (coronary plaque ≤50%) in 87 (46.5%) patients and obstructive CAD (>50%) in 35 (18.8%) patients. A total of 20 major cardiac events (3 myocardial infarctions, 16 cardiac revascularizations, 1 unstable angina) occurred during a mean follow-up of 24 months. One noncardiac death occurred. Seventeen events occurred in the group of patients with obstructive CAD and three events occurred in the group of nonobstructive CAD. The event rate was 0% among patients with normal coronary arteries at CTCA. CTCA has a 100% negative predictive value for major cardiac events at 24-month follow-up in patients with normal coronary arteries.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Hamon M, Biondi-Zoccai G, Malagutti P, Agostoni P, Morello R, Valgimigli M, Hamon M (2006) Diagnostic performance of multislice computer tomography of coronary arteries as compared with conventional invasive coronary angiography: a meta-anaysis. J Am Coll Cardiol 48:1896–1910

    Article  PubMed  Google Scholar 

  2. Mollet NR, Cademartiri F, van Mieghem CA, Runza G, McFadden EP, Baks T, Serruys PW, Krestin GP, de Feyter PJ (2005) High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 112:2318–2323

    Article  PubMed  Google Scholar 

  3. Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557

    Article  PubMed  Google Scholar 

  4. Abdulla J, Abildstrom SZ, Gotzsche O, Christensen E, Kober L, Torp-Pedersen C (2007) 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis. Eur Heart J 28:3042–50

    Article  PubMed  Google Scholar 

  5. Morise AP, Haddad WJ, Beckner D (1997) Development and validation of a clinical score to estimate the probability of coronary artery disease in men and women presenting with suspected coronary disease. Am J Med 102:350–356

    Article  PubMed  CAS  Google Scholar 

  6. Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M Jr, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832

    Article  PubMed  CAS  Google Scholar 

  7. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, Mc Goon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40

    PubMed  CAS  Google Scholar 

  8. Schroeder S, Kuettner A, Leitritz M, Janzen J, Kopp AF, Herdeg C, Heuschmid M, Burgstahler C, Baumbach A, Wehrmann M, Claussen CD (2004) Reliability of differentiating human coronary plaque morphology using contrast-enhaned multislice spiral computed tomography: a comparison with histology. J Comput Assist Tomogr 28:449–454

    Article  PubMed  Google Scholar 

  9. Fine JJ, Hopkins CB, Ruff N, Newton FC (2006) Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease. Am J Cardiol 97:173–174

    Article  PubMed  Google Scholar 

  10. Leschka S, Alkadhi H, Plass A, Desbiolles L, Grunenfelder J, Marincek B, Wildermuth S (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487

    Article  PubMed  Google Scholar 

  11. Ropers D, Rixe J, Anders K, Kuttner A, Baum U, Bautz W, Daniel WG, Achenbach S (2006) Usefulness of multidetector row spiral computed tomography with 64- × 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348

    Article  PubMed  Google Scholar 

  12. Nikolaou K, Knez A, Rist C, Wintersperger BJ, Leber A, Johnson T, Reiser MF, Becker CR (2006) Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol 187:111–117

    Article  PubMed  Google Scholar 

  13. Schuijf JD, Pundziute G, Jukema JW, Lamb HJ, van der Hoeven BL, de Roos A, van der Wall EE, Bax JJ (2006) Diagnostic accuracy of 64-slice multislice computed tomography in the noninvasive evaluation of significant coronary artery disease. Am J Cardiol 98:145–148

    Article  PubMed  Google Scholar 

  14. Pundziute G, Schuijf JD, Jukema JW, Boersma E, de Roos A, van der Wall E, Bax JJ (2007) Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease. J Am Coll Cardiol 49:62–70

    Article  PubMed  Google Scholar 

  15. Min JK, Shaw LJ, Devereux RB, Okin PM, Weinsaft JW, Russo DJ, Lippolis NJ, Berman DS, Callister TQ (2007) Prognostic value of multidetector coronary computed tomographic angiography for prediction of all-cause mortality. J Am Coll Cardiol 50:1161–1170

    Article  PubMed  Google Scholar 

  16. Gilard M, Le Gal G, Cornily JC, Vinsonneau U, Joret C, Pennec PY, Mansourati J, Boschat J (2007) Midterm prognosis of patients with suspected coronary artery disease and normal multislice computed tomographic findings: a prospective management outcome study. Arch Intern Med 167:1686–1689

    Article  PubMed  Google Scholar 

  17. Ostrom M, Gopal A, Ahmadi N, Nasir K, Yang E, Kakadiaris I, Flores F, Mao S, Budoff M (2008) Mortality incidence and the severity of coronary atherosclerosis assessed by computed tomography angiography. J Am Coll Cardiol 52:1335–1343

    Article  PubMed  Google Scholar 

  18. Gaemperli O, Valenta I, Schepis T, Husmann L, Scheffel H, Desbiolles L, Leschka S, Alkadhi H, Kaufmann P (2008) Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease. Eur Radiol 18:1162–1173

    Article  PubMed  Google Scholar 

  19. Shaw LJ, Iskandrian AE (2004) Prognostic value of gated myocardial perfusion SPECT. J Nucl Cardiol 11:171–185

    Article  PubMed  Google Scholar 

  20. Cheitlin MD, Alpert JS, Armstrong WF, Aurigemma GP, Beller GA, Bierman FZ, Davidson TW, Davis JL, Douglas PS, Gillam LD, Lewis RP, Pearlman AS, Philbrick JT, Shah PM, Williams RG, Ritchie JL, Eagle KA, Gardner TJ, Garson A, Gibbons RJ, O’Rourke RA, Ryan TJ (1997) ACC/AHA guidelines for the clinical application of echocardiography: executive summary. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Clinical Application of Echocardiography). Developed in collaboration with the American Society of Echocardiography. J Am Coll Cardiol 29:862–879

    PubMed  CAS  Google Scholar 

  21. Yao SS, Qureshi E, Sherrid MV, Chaudhry FA (2003) Practical applications in stress echocardiography: risk stratification and prognosis in patients with known or suspected ischemic heart disease. J Am Coll Cardiol 42:1084–1090

    Article  PubMed  Google Scholar 

  22. Metz LD, Beattie M Hom R, Redberg RF, Grady D, Fleischmann KE (2007) The prognostic value of normal exercise myocardial perfusion imaging and exercise echocardiography: a meta-analysis. J Am Coll Cardiol 49:227–237

    Article  PubMed  Google Scholar 

  23. Maruyama T, Takada M, Hasuike T, Yoshikawa A, Namimatsu E, Yoshizumi T (2008) Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography comparison with retrospective electrocardiogram-gated helical scan. J Am Coll Cardiol 52:1450–1455

    Article  PubMed  Google Scholar 

  24. Shuman W, Branch K, May J, Mitsumori L, Lockhart D, Dubinsky T, Warren B, Caldwell T (2008) Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248:431–437

    Article  PubMed  Google Scholar 

  25. Herzog B, Husmann L, Burkhard N, Gaemperli O, Valenta I, Tatsugami F, Wyss C, Landmesser U, Kaufmann P (2008) Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience. Eur Heart J 29:3037–3042

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Filippo Cademartiri.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Aldrovandi, A., Maffei, E., Palumbo, A. et al. Prognostic value of computed tomography coronary angiography in patients with suspected coronary artery disease: a 24-month follow-up study. Eur Radiol 19, 1653–1660 (2009). https://doi.org/10.1007/s00330-009-1344-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-009-1344-3

Keywords