Introduction

The heart relies on myocardial perfusion for supply of oxygen and substrates necessary to maintain contractile function [11]. Under physiological conditions, perfusion is tightly matched to metabolic demand. This is achieved by modulating coronary vascular resistance through adjustment of vascular tone. This process is under metabolic, endothelial, myogenic, and neurohumoral control [5, 16, 70]. In the presence of a pathological increase in vascular resistance, as that resulting from a stenosis of an epicardial artery, regulatory mechanisms may become progressively exhausted and blood supply may fall short relative to demand, promptly resulting in myocardial ischemia as myocardial oxygen extraction can only slightly increase in ischemic conditions. Traditionally, identification and treatment of augmented coronary resistance have focused on obstructive atherosclerosis of the epicardial arteries. However, over the past two decades it has become increasingly apparent that augmented vascular resistance may also reside in the coronary microcirculation in a number of clinical conditions [13, 39]. Moreover, the severity of coronary microvascular dysfunction has been shown to be a powerful predictor of an adverse clinical outcome [14, 78]. Consequently, accurate assessment of coronary microvascular resistance (CMVR) has gained considerable interest, including the identification of potentially modifiable determinants for therapeutic purposes.

Conventional flow reserve measurements, using invasive and noninvasive techniques, are frequently used to test the integrity of the microcirculation [95, 102]. As will be discussed, however, their dependence on hemodynamic conditions and cardiac function limits the conclusions that can be derived from these measurements. Recent advances in different imaging modalities offer the possibility to quantify myocardial perfusion and resistance in absolute terms and to correct for some of these confounders. This review is intended to provide an update on the quantitative assessment of CMVR, together with its strengths and limitations, with particular emphasis on the noninvasive approach.

Coronary microvascular resistance

Resistance equals pressure-gradient divided by flow. In the case of the heart, the mean aortic to coronary back pressure (vide infra) gradient divided by total sinus coronary blood flow yields total coronary resistance (mmHg mL min−1), although it must be acknowledged that Thebesian flow draining directly to the ventricular and atrial cavities is unaccounted for [93]. The coronary system can roughly be divided into three separate resistance components, being the conduit epicardial arteries, the arterioles, and the capillary–venous compartment [70, 106]. Under normal physiological conditions, resistance is principally determined by vasomotor regulation of the arterioles with a diameter of less than 400 μm and flow is kept constant over a wide range of perfusion pressures, i.e., flow is autoregulated [16, 70, 76, 118]. The control mechanisms involved in autoregulation are numerous and have been reviewed elsewhere [5, 44, 106]. The plateau level of resting flow, as depicted in Fig. 1, is matched to oxidative metabolism, which in turn is predominantly determined by heart rate, wall stress, and contractile state [11]. Therefore, knowledge of coronary resistance under baseline conditions mainly reflects basal metabolism, although it is also influenced by vascular rarefaction in LV hypertrophy and conditions where arterial oxygen content is reduced such as anemia [12]. Only when faced with a subtotal stenosis of an epicardial artery will coronary resistance be significantly augmented and cannot be compensated for by autoregulation [108]. In the absence of collaterals, this condition results in hampered resting perfusion and ultimately invariably results in tissue necrosis, although mild reductions in resting flow may be tolerated for an unknown period of time [42, 119]. However, when autoregulation is exhausted, minimal resistance can be calculated. Thus, when one wants to evaluate the performance of the microvascular bed and quantify minimal CMVR, the following conditions should ideally be met: (1) exclude the presence of obstructive epicardial coronary artery disease or determine driving pressure distal to an epicardial stenosis, (2) quantify flow, (3) induce maximal vasodilatation while recording pressure and flow, and (4) correct for coronary back pressure. The latter parameter is, however, difficult to measure as it is composed of multiple hemodynamic factors such as central venous pressure, coronary venous pressure, extravascular compressive forces such as LV end-diastolic pressure, and is further complicated by zero flow pressure [3]. As discussed below in more detail, in clinical studies many investigators, therefore, assume it to be zero or to be equivalent to right atrial pressure. In conditions of high arterial perfusion pressure and low coronary back pressure, this assumption is of little significance. In contrast, when arterial perfusion pressure is low, e.g., distal to a significant epicardial coronary stenosis, and/or coronary back pressure is high, this approach will result in potential erroneous quantification of CMVR [118].

Fig. 1
figure 1

Autoregulation maintains flow during constant metabolism. Over the autoregulation range, i.e., the plateau of the autoregulation curve, flow is rather constant for a range of perfusion pressures. The level of the plateau is related to the metabolic state of the heart. The dashed line indicates maximal pharmacological vasodilation. The dotted line shows the maximal physiological dilation, which is slightly smaller than can be reached pharmacologically. The flow reserve is given by the ratio (B + A)/A. Flow reserve is dependent on the basal level of myocardial metabolism, irrespective of minimum hyperemic coronary resistance. It should be noted that these relations are derived from isolated heart preparation studies where perfusion pressure and workload can be controlled independently. Human physiology in vivo usually operates within a smaller range of pressure and flow, and the close correlation between systolic pressure and oxidative metabolism results in a much narrower plateau phase of relative constant flow. Reprinted with permission from Westerhof et al. [118]

It is also important to realize that minimal CMVR is governed by intravascular as well as extravascular forces [118]. The former represents the conductance of the coronary microvessels themselves, whereas the latter is affected by mechanical cross-talk between contracting myocardium and the coronary vasculature such as diastolic perfusion time, cardiac contraction, and LV diastolic wall stress [44, 118]. In other words, CMVR is determined not only by intrinsic characteristics of the microvessels, but also by cardiac function where increased intra- and extra-myocardial forces of the beating heart can impede coronary flow.

Coronary flow reserve

Coronary flow reserve (CFR) is defined as the ratio of peak hyperemic to resting flow. At a first glance, a reduction in flow reserve seems indicative of an increase in minimal coronary resistance and, in the absence of obstructive epicardial coronary artery disease, is therefore frequently used as an index of microvascular dysfunction. Of interest, absolute quantification of perfusion is not mandatory for the calculation of CFR, as the ratio of semi-quantitative perfusion indices will also yield a flow ratio. Unfortunately, as can be appreciated from Fig. 1, for a given level of hyperemic flow, CFR strongly depends on changes in the plateau level of resting perfusion. Although normalization of resting flow for heart rate and blood pressure may standardize this parameter, its correction remains incomplete. The magnitude of hyperemic perfusion, in turn, is likewise affected by hemodynamic conditions such as driving pressure and heart rate. The dependence of flow reserve on hemodynamic conditions and cardiac function therefore limits its use as a reliable and reproducible marker of microvascular disease [88]. Minimal CMVR should therefore be considered a more quantitative measure of microvascular function and the preferred parameter to study microvascular disease.

Invasive quantification of minimal CMVR

Invasive catheter-based quantification of minimal CMVR can be performed at a global or regional level [56, 101]. For the global approach, the coronary sinus is selectively catheterized and flow is measured with the use of the thermodilution technique. This technique is based on the general indicator dilution theory [74], which has been validated in the human heart to quantify global myocardial blood flow [28]. After a bolus or continuous injection of saline of a known volume and temperature, the temperature curve registration, a few centimeters distal to the injection site, allows for the computation of absolute volumetric flow, expressed in mL min−1. The regional approach requires catheterization of one of the major coronary arteries and flow can again be measured using the thermodilution technique [82]. Alternatively, flow velocity can be measured with the use of a Doppler guide wire advanced into the epicardial coronary artery [25]. Current state-of-the-art single guide wires allow for the assessment of flow velocity and pressure simultaneously to determine CMVR [2, 82, 98]. As the Doppler signal yields flow velocity only, conversion to volumetric flow requires exact knowledge of the vessel lumen dimensions, i.e., the cross-sectional area, that can be obtained through either quantitative coronary angiography (QCA) or intravascular ultrasound (IVUS) [32, 96, 114].

The measurements need to be performed during maximal pharmacological vasodilatation induced either regionally (i.e., intracoronary adenosine bolus dose 30–60 or 20–30 μg for left or right coronary artery, respectively, or papaverine 15 or 10 mg, respectively) or systemically (i.e., intravenous adenosine dose 140 μg kg−1 min−1 or dipyridamole dose 0.56 mg kg−1) to achieve minimal coronary resistance [56]. It should be noted that the level of vasodilatation induced with dipyridamole is slightly less than with adenosine, leading to small differences in minimal hyperemic CMVR [15]. Furthermore, vasodilatation induced with these pharmacological vasodilating agents (i.e., causing uncoupling between perfusion and metabolic demand) appears to somewhat exceed the physiologically mediated response (i.e., retained coupling between perfusion and metabolic demand) (Fig. 1) [50, 118]. Of interest, alpha-adrenergic-mediated coronary vasoconstriction may even precipitate an increase in CMVR [39, 40]. Under physiologic circumstances, there is very little alpha-adrenergic coronary vasomotor tone at rest, and hyperemic blood flow is only somewhat blunted [69]. Under conditions such as endothelial dysfunction and atherosclerosis, however, alpha-adrenergic-mediated coronary vasoconstriction is enhanced [6, 53, 120]. In patients with established coronary artery disease, alpha-adrenoceptor activation induces augmented coronary vasoconstriction, which is powerful enough to induce myocardial ischemia [6, 89]. Both, alpha1- and alpha2-adrenoceptors mediate such coronary vasoconstriction, with alpha2-adrenoceptors more predominant in the microcirculation [17, 41]. Notably, reflex alpha-adrenergic coronary vasoconstriction is also elicited during coronary interventions [34, 49], and this contributes to postinterventional contractile dysfunction [36, 37]. The distribution pattern of increased CMVR under these ischemic conditions appears to be very heterogeneous [90]. Infusion of adenosine subsequently lowers minimal CMVR and alleviates signs and symptoms of ischemia [89, 90]. Antagonizing the α-adrenergetic receptors may further enhance hyperemic perfusion on top of the aforementioned vasodilating agents, particularly during pathological conditions such as ischemia, in part mediated by the prolongation of diastolic perfusion time [35, 39, 64]. Finally, although beyond the scope of this review, endothelium coronary microvascular function can be tested separately through endothelium-dependent-mediated vasodilating agents, such as intracoronary acetylcholine.

Using pressure–flow relations measured within a coronary artery, the diastolic coronary pressure–flow (P–F) relationship can also be used to assess microvascular resistance. This relationship is essentially linear at perfusion pressures >40 mmHg but is appreciably curved at lower pressures. The curvilinearity is explained by gradually declining diameters of microvascular vessels at low pressures. Diastolic coronary flow stops at a coronary pressure far above right atrial pressures. The zero flow pressure is considered as a back pressure that affects coronary driving pressure. The mechanism and interpretation of the zero flow pressure are still a matter of debate [59, 100]. Two theories have been proposed to explain this phenomenon: a vascular waterfall theory and an intramyocardial pump model theory. In the former, vascular collapse is assumed to take place at very low pressure. The latter model is explained by the fact that the intramyocardial blood volume and blood pressure change more slowly than arterial pressure due to large time constants for charging and discharging the intramyocardial compliance. So, intramyocardial blood is still streaming even when epicardial coronary blood flow has stopped. The curvilinearity of the P–F relation implies that microvascular resistance does not remain constant during one cardiac cycle. Furthermore, to determine the zero flow pressure, a very long diastole is needed; in a normal clinical situation, the next cardiac cycle is starting long before coronary flow of the previous cardiac cycle has become zero. For these reasons, the P–F relation and zero flow pressure are very hard to use in clinical practice and therefore will not be further discussed in this review. In clinical studies, right atrial pressure can be advocated as an estimate of coronary back pressure to calculate CMVR.

Strengths and limitations

The major advantage of the catheter-based approach is the fact that coronary angiography can be performed to exclude obstructive atherosclerosis of the epicardial arteries during the same session as the CMVR measurements. Moreover, in the presence of an epicardial obstructive stenosis, regional CMVR can be determined by assessing pressure and flow distal to the lesion [72]. In these instances, distal pressure measurements can distinguish coronary epicardial from microvascular resistance. The contribution of the epicardial stenosis to total coronary resistance can additionally be evaluated by determining the pressure drop over the epicardial stenosis (fractional flow resserve, FFR) [71, 72]. Finally, acute effects of (coronary) interventions on CMVR can be monitored, particularly in target vessel coronary arteries [89, 112]. There are, however, several limitations that deserve attention.

First, the thermodilution technique has drawbacks. Stable positioning of the catheter, especially in the coronary sinus, can be difficult [28, 73, 117]. Furthermore, absolute quantification of flow requires accurate registration of the temperature and volume of the injected indicator (saline) at the injection and the downstream temperature recording at the distal site. These types of measurements have proven to be problematic and display relatively high variability, e.g., due to incomplete mixing of saline and blood [73, 117]. Mixing problems appear to be smaller for bolus injections than for continuous infusion of saline [2].

Given these technical limitations, Pijls and colleagues have developed and validated a simplified thermodilution model where an index rather than quantitative flow is obtained by registration of the mean transit time of the indicator, disregarding absolute temperature changes [19, 82]. Thereafter, a semi-quantitative, unit-less index of microcirculatory resistance can be calculated [26]. Although experience is limited, mean transit time could also be determined using X-ray densitometry [38].

Second, although blood flow velocity measurements from Doppler signals are robust, determination of the cross-sectional area of the vessel for subsequent conversion to absolute flow remains problematic [25]. QCA requires angiography from at least two, but preferably more, angles and is accompanied by time consuming post-processing [32, 96]. IVUS yields qualitatively excellent images and accurate cross-sectional area estimates, but is expensive and less widely available [114]. To circumvent the additional cross-sectional area imaging, a similar index of resistance as mentioned above has been introduced by Meuwissen and co-workers [75]. The so-called velocity-based index of CMVR equals the central arterial pressure divided by flow velocity obtained with Doppler and is expressed in mmHg cm−1 s−1.

Third, in the presence of an obstructive coronary lesion, collateral flow becomes increasingly important with increasing stenosis severity. The above-described techniques do not account for collateral flow and therefore overestimate actual microvascular resistance [1]. Although this effect can be determined by measuring pressure and flow distal to the lesion during wedging of the coronary artery, these measurements are cumbersome and introduce additional room for error that hinder the interpretation of the obtained data. Apart from these technical limitations, the invasive nature of the procedure, exposure to ionizing radiation, and use of nephrotoxic contrast agents are general limitations that must also be taken into account.

Noninvasive quantification of minimal CMVR

Noninvasive measurement of CMVR can be obtained with positron emission tomography (PET), cardiovascular magnetic resonance imaging (CMR), or echocardiography. As will be discussed below, each of these imaging modalities allows for the absolute quantification of perfusion with the aid of radiolabeled or contrast agents, and also enable to detect regional variability [29, 33, 90, 105]. Characteristics of each modality are given in Table 1. During these noninvasive perfusion studies, the coronary driving pressure can simply be obtained by measuring mean arterial blood pressure with the use of a sphygmomanometer. As already mentioned, systemic vasodilatation is usually achieved by the infusion of adenosine or dipyridamole.

Table 1 Characteristics of different imaging modalities regarding absolute quantification of myocardial perfusion

Depending on the spatial resolution of the imaging modality, perfusion and resistance can even be distinguished between the subendocardial and subepicardial layers. The latter is of pathophysiological importance as ischemia principally occurs in the subendocardium [27, 43]. Furthermore, diastolic perfusion time has proved to be an important determinant of subendocardial ischemia and can simultaneously be assessed using echocardiography and CMR [27, 109].

The major disadvantage that characterizes these noninvasive approaches pertains to the inability of these imaging modalities to exclude the proximal pressure drop in obstructive epicardial coronary artery disease to distinguish microvascular from epicardial stenosis resistance. Although it is important to bear in mind that coronary microvascular dysfunction is often a global process, reference areas with relatively preserved hyperemic perfusion can be still used to quantify CMVR. The adjacent more severely blunted perfusion areas are then assumed to be caused by epicardial lesions.

General considerations of perfusion quantification

The general principle of quantitative perfusion imaging is based on the registration of the exchange of tracer concentration between arterial blood and myocardial tissue over time, where the ideal perfusion tracer accumulates in or clears from myocardium proportionally to MBF and is not affected by the magnitude of flow and pathophysiological conditions [54]. For all tracers, the activity concentration in myocardium (i.e., the tissue response to the injected tracer) is dependent on the product of MBF, the tracer extraction fraction, and the arterial input function. In other words, MBF can be calculated when myocardial and arterial concentrations are measured over time and tracer extraction fraction is known. The latter value equals unity for completely freely diffusible tracers, although for most tracers, the first pass extraction is less than 1 and declines nonlinearly relation with increasing MBF, complicating quantification of flow.

Positron emission tomography

For PET perfusion imaging, two tracers in particular have been well validated and are routinely used for quantification of myocardial blood flow: oxygen-15 labeled water (H 152 O) and nitrogen-13 labeled ammonia (13NH3) [7, 94]. The scanning procedure for both tracers is comparable where after an intravenous bolus injection of the perfusion tracer simultaneously a dynamic emission is performed. Figure 2 shows an example of such a dynamic cardiac 13NH3 PET acquisition and its corresponding time activity curves for regions of interest derived from the LV cavity and the myocardium.

Fig. 2
figure 2

Serially acquired short axis PET images following the intravenous injection of 13N-ammonia. Ten-second images are shown. Notice in the second image the activity in the right ventricular cavity, and visualization of the left ventricular blood pool on the next image, and thereafter accumulation of the tracer in the myocardium and clearance from blood. The corresponding time–activity curves for arterial blood and myocardial tissue are also displayed. The dynamic flux of tracer from arterial blood to tissue is modeled to convey absolute units of perfusion. Reprinted with permission from ‘PET: molecular imaging and its biological applications’, edited by Michael E. Phelps (2004) Springer-Verlag, New York, Inc

Based on the known biological behavior of the two tracers, kinetic compartment models have been developed to quantify MBF in absolute terms (mL min−1 g−1). There are, however, some important differences in characteristics between H 152 O and 13NH3 MBF measurements that are listed in Table 2. Two particular technical aspects are worth discussing in more detail.

Table 2 Characteristics of oxygen-15-labeled water (H 152 O) and nitrogen-13-labeled ammonia (13NH3) for PET perfusion imaging

First, H 152 O is a metabolically inert and freely diffusible molecule which has a virtual complete extraction into the myocardium, independent of flow rate and metabolic state. Therefore, regional differences in myocardial tissue response are solely dependent on perfusion, rendering this tracer ideal for quantification of flow. Conversely, the 13NH3 extraction fraction decreases with increasing flow rates, leading to underestimation of perfusion with higher flow values unless of course they are corrected for by the tracer compartment model. In fact, these corrections have been thoroughly tested and perfusion values obtained with H 152 O and 13NH3 yield comparable results and match with the gold standard of microsphere-determined perfusion [9, 79].

Second, the modeling procedures of the tracers differ in that perfusion is estimated from the wash-out phase of the radiolabeled tracer in H 152 O studies, whereas for 13NH3 the myocardial uptake is used [47, 65]. These methodological differences do not affect perfusion measurements in normal myocardium [15, 79], but lead to different flow estimates in myocardium with scar tissue [9]. As perfusion in scar tissue is negligible, uptake of flow tracers will take place in viable or normal myocardium only [48]. Consequently, wash-out of H 152 O is related only to the water perfusable tissue fraction so that estimates of blood flow are limited to normal or viable myocardium. Estimates of perfusion from the wash-out phase with H 152 O will therefore reflect flow in viable perfusable tissue only. In contrast, estimating perfusion derived from tracer uptake using 13NH3 will reflect the admixture of scar and viable tissue, i.e., transmural perfusion [60]. In practice, this means that, in the presence of scar tissue, perfusion measured with 13NH3 will yield lower values compared with H 152 O in direct proportion to the magnitude of the present myocardial scar. This technical feature has been used to quantify coronary CMVR in residual viable myocardium after a myocardial infarction in humans using H 152 O PET [71, 72, 107].

Strengths and limitations

For the last two decades, PET has served as the gold standard for noninvasive absolute quantification of myocardial blood flow (MBF) and CMVR [54]. Both tracers have been shown to accurately quantify MBF in absolute units over a wide flow range and correlate well with values obtained after injection of radiolabeled microspheres, both at a regional and global level [9]. Furthermore, reproducibility was shown to be good [55, 77], and PET studies have provided normal references values for both resting and hyperemic MBF in healthy volunteers [15]. In addition, the relatively short half-life of the tracers, particularly H 152 O (120 s), allows for serial measurements within a single session which enables the investigation of multiple interventions on perfusion and resistance [63]. Finally, in recent years, parametric imaging has significantly reduced the post-processing time by the omission of elaborate (manual) region of interest analysis, making this technique increasingly operator friendly [8, 31].

On the downside, perfusion PET suffers from its limited availability and high costs, which are mainly related to the necessity of an onsite cyclotron and expertise regarding the preparation and administration of the involved radiotracers. Also, PET imaging is accompanied by exposure to ionizing radiation, although the burden is relatively low using these short-lived tracers. Furthermore, the spatial resolution of PET is relatively low (~5 mm), resulting in partial volume and spillover effects. Sophisticated kinetic modeling parameters, however, can correct for these effects and advances in imaging instrumentation have even enabled the distinction between subendocardial and subepicardial perfusion, not only in the hypertrophied human heart but also in the normal sized myocardial wall [61, 85, 86]. Finally, although PET is the method of choice for noninvasive assessment of perfusion and metabolism, it does not provide suitable anatomical information compared with CMR and echocardiography. However, state-of-the-art hybrid imaging systems combining PET and CT offer anatomical, functional, and metabolic information in a single scan session [20, 62, 91, 92, 97].

Cardiovascular magnetic resonance imaging

Although initial attempts for (semi)quantitative assessment of MBF using CMR focused on velocity-encoded phase contrast imaging of either the proximal course of the coronary arteries or the coronary sinus [46, 110], recent myocardial CMR perfusion imaging approaches are mainly based on the changes in myocardial signal intensities during first pass of paramagnetic extracellular contrast agents, i.e., gadolinium chelates [51]. After an intravenous bolus injection of the contrast agent, an electrocardiogram-gated acquisition of approximately 30–60 s is started and myocardial and arterial signal intensities are recorded over time. The patient is normally asked to suspend breathing for 10–15 s after the bolus injection so that the initial myocardial contrast-enhancement can be observed without interference from breathing motion, although image quality is generally not affected by the breathing motion, but causes slice misregistration. Figure 3 displays such an imaging sequence. During the first pass of the contrast agent, a fraction of it rapidly diffuses through the capillary walls into the interstitium, where it reduces the T1 relaxation time and increases the signal intensity of the protons surrounding the contrast molecules. The myocardial signal intensity response to the arterial input, however, depends not only on the perfusion, but also on the tissue blood volume, the size of the extravascular compartment, and the degree of capillary permeability, which complicates quantitative analysis that must account for all these unknown variables [103, 104]. Therefore, for the purpose of only determining tissue blood flow, a model-independent approach based on the central volume principle of Zierler [121] was developed that focuses on the initial amplitude of the myocardial tissue response, which is, in theory, related to flow only. The area under the impulse response curve represents the (dynamic) volume of distribution during the first pass, and can provide a measure of vascular volume if an intravascular tracer is used. For extracellular tracers, such as gadolinium diethylenetriaminepenta-acetic acid, the impulse response is characterized by an initial rapid decay related to the vascular phase of contrast transit, and a prolonged tail that corresponds to the delayed wash-out of tracer that has passed from the capillaries into the interstitial space. The application of the model-independent analysis based on the central volume principle requires numerical deconvolution of the measured signal enhancement in tissue with an arterial input function derived from the measured signal enhancement in blood (e.g., in the ascending aorta or the left ventricular cavity). This model for absolute quantification of flow has subsequently been validated in animal experiments by comparing the blood flow measurements with radio-labeled microspheres [52], and thereafter been used in more large scaled clinical studies for the assessment of microvascular function [81, 87].

Fig. 3
figure 3

CMR short axis images (ad) of the first pass of gadolinium contrast and activity curves of contrast (expressed in arbitrary units) plotted against time for the arterial left ventricular blood pool and two myocardial regions. A perfusion defect can be observed both visually on the images and from the activity registration in the anteroseptal area, where the peak intensity and slope of the curve are reduced. Note that tracer uptake in tissue occurs just seconds after the peak intensity of the input curve and remains fairly stable in the minute thereafter, as the contrast agent resides in the extracellular matrix after diffusion from the capillaries. Also note the recirculation of contrast after 25 s that induces a second peak in arterial blood. Because the physiological behavior of the tracer is dependent on a variety of physiological parameters that cannot be modeled, only peak intensity levels of arterial blood and tissue are used to determine perfusion in absolute terms

Strengths and limitations

Myocardial perfusion imaging using CMR has the advantage of high spatial resolution, no use of ionizing radiation, the use of readily available contrast agents, and no attenuation problems related to, e.g., overlying breast shadow. Furthermore, next to the information pertaining to perfusion, accurate assessment of regional myocardial wall motion and, using late-contrast enhanced images (approximately 10–15 min after injection), tissue morphology can be obtained in the same setting [10, 57, 58]. Moreover, advances in CMR imaging have now enabled accurate delineation of subendocardial and subepicardial perfusion [83, 84]. In combination with CMR-estimated diastolic perfusion time, not only regional resistance but also some of its determinants can be evaluated. There are, however, some important technical limitations that hamper the routine quantification of perfusion with CMR.

First and foremost importance, to achieve an adequate signal-to-noise ratio of the myocardial tissue enhancement as displayed in Fig. 3, relatively large doses of gadolinium are administered (from 0.05 up to more than 0.1 mmol kg−1). At these concentrations, however, the linear relationship between the measured signal intensity in the LV cavity and the actual contrast concentrations levels off. Therefore, for quantification purposes where the arterial input concentrations of contrast must reliably be defined, one should use much lower doses of gadolinium, i.e., in the order of 0.005–0.03 mmol kg−1, to retain a linear relation between contrast concentration and the obtained signal. Unfortunately, these lower doses result in decreased contrast to noise ratios and loss of the possibility for visual analysis of the myocardial tissue response. To circumvent this problem, Christian et al. [18] have recently introduced and validated the so-called dual-bolus approach. Low and high concentration bolus injections of contrast are administered serially within a few-second interval, where the first is used for registration of the arterial input function and the second for tissue response. In this manner, high signal-to-noise tissue images are generated, additionally allowing qualitative visual interpretation, and fully quantitative computation can be performed using the input curve. In addition, the signal enhancement in tissue, despite being much lower than in the blood pool, may still be compromised by some saturation effects from the signal contributed by the vascular volume fraction in tissue. Therefore, one of the original proponents of the dual-bolus approach recently proposed a method for nonlinear myocardial signal intensity correction, but still assuming that myocardial tissue is a homogeneous space [45]. In addition to the dependence of the myocardial signal on the underlying structure of the tissue and the distribution of the contrast agent, one should also note that the 1H signal is not only affected by close contact with the contrast agent, but also by the exchange of water between different spaces in tissue, including spaces not directly accessible to the contrast agent [23, 24, 67].

Second, post-processing requires manual definition of myocardial regions of interest or segmentation along the endo- and epicardial borders, which is quite time consuming. Although efforts are being made to map perfusion on a pixel-by-pixel basis, these new analysis techniques are not yet routinely applicable [30]. Furthermore, the process of manual region delineation is complicated by patient motion during the breath-hold acquisition. In particular, the stress study is prone to motion artifacts that require frame by frame adjustment of the regions of interest.

Finally, recent attention has focused on the toxicity of gadolinium-based contrast agents, particularly in patients with chronic renal failure where its use is associated with nephrogenic systemic fibrosis [66]. In fact, these side-effects have restricted its use to patients with a glomerular filtration rate of at least 30 mL min−1 [115]. Also, some general restrictions prohibit perfusion imaging with CMR, such as claustrophobia, myocardial arrhythmias, and implanted devices.

Echocardiography

Myocardial contrast echocardiography (MCE) for quantification of perfusion has become feasible with the recent development of an encapsulated microbubble contrast agent that remains confined to the intravascular space and behaves similarly as red blood cells in terms of rheology [68]. The microbubbles are continuously administered intravenously in order to reach a steady state with concentrations in arterial blood and myocardial tissue relatively constant. Subsequently, a high-power ultrasound pulse applied within the acoustic beam destroys the bubbles and the void is replenished within few seconds (Fig. 4a). The time–video intensity registration can be fitted to an exponential equation, i.e., y = A (1 – e−β t), where A represents the (mainly capillary) myocardial blood volume and β the rate constant that indicates the flow velocity of blood (Fig. 4b) [116]. The product of the two, therefore, provides an estimate on myocardial blood flow, which correlates with perfusion in canine experiments [116].

Fig. 4
figure 4

a Example of intravenous myocardial contrast echocardiography, 3-chamber view during hyperemia: precontrast image (a), high mechanical ultrasound pulse (b), and subsequent replenishment of contrast (ch). b Example of mono-exponential time–video intensity curve. The slope of the initial phase of the curve represents the microbubble flow velocity, whereas the plateau phase indicates blood volume. c Region-of-interest placement for myocardial regions with adjacent left ventricular blood pool in a four-chamber view of a healthy volunteer. Reprinted with permission from Dijkmans et al. [21] (a, b), and from Vogel et al. [113] (c)

True quantification, however, is hindered by the fact that estimated myocardial blood volume is subjected to attenuation artifacts, such as the microbubbles present in the left ventricular cavity, and heterogeneity of the acoustic beam. Vogel et al. have recently circumvented this issue by standardizing the myocardial blood volume signal to the adjacent left ventricular blood pool signal (Fig. 4c). As these signals are theoretically affected to a similar degree by these artifacts, they are filtered out using this approach [113]. Indeed, absolute quantification of perfusion with MCE correlated nicely with PET-obtained values in humans [113].

Strengths and limitations

Although MCE is relatively new in the field of perfusion imaging and requires operator demands that are not easily met, the potential for this technique is evident as echocardiography is widely available, and is characterized by high temporal and spatial resolution, and performs well in additional functional cardiac imaging. Despite these advantages, compared with PET and CMR, MCE must currently be considered the least accurate and attractive noninvasive perfusion imaging modality for two reasons.

First, there are some technical concerns. As commonly known, echocardiography suffers from a poor acoustic window in a not inconsequential percentage of patients. In general, about 10–15% of echo exams are of poor quality. Moreover, even when these patients have been excluded, a recent MCE perfusion study has shown that an additional 20% of myocardial segments were not suitable for the analysis [21]. Furthermore, the number of validation studies with MCE that have implemented the above-described model is limited [21, 113]. Unfortunately, the initial promising results of Vogel et al. [113] could not be reproduced by Dijkmans and co-workers [21], as the latter study revealed significantly more scatter in the obtained perfusion data as compared with PET. One of the possible explanations for the inaccuracy of the measurements, next to distortions in image quality, could be that the model assumes linearity between contrast concentrations and measured video intensity. This assumption, however, is incorrect in the higher range of microbubble concentrations as observed in the left ventricular cavity [99, 116]. Another issue, and similar to CMR, is the tedious post-processing procedure that requires manual definition of regions of interest, prohibiting its use on a larger scale.

Second, there is an ongoing debate with respect to safety of the microbubble contrast agent [22]. Adverse allergic reactions have been frequently reported. Although these side effects generally do not result in permanent damage, it has led to regulations restricting the use of some brands in severely cardiovascular compromised patients [22]. Use of these agents, therefore, requires the attention of a physician at all times. In addition, both dog [4] and human [111] experiments have shown that the destruction of microbubbles by the ultrasound beam can result in microvascular damage. Although relatively low mechanical pulses seem reasonably safe, they in turn may result in incomplete bubble destruction, which reduces the quality of the study [80].

Summary and conclusions

With the growing awareness that coronary microvascular dysfunction is an important pathophysiological component in many cardiac conditions, comes the necessity to accurately assess the functional status of the microcirculation [13]. In trying to achieve this goal, absolute quantification of perfusion and pressure to determine minimum microvascular resistance plays a central role [70, 118]. This review has discussed the pros and cons of the currently available invasive and noninvasive techniques regarding these measurements. It can be concluded that the invasive approach is the preferred method in patients with epicardial obstructive coronary atherosclerosis as microvascular resistance can be determined distal to the epicardial lesion. Also, invasive measurements are most suitable to investigate acute effects of interventions. The noninvasive measurements with PET, CMR, or MCE to assess the coronary microcirculation can be used in patients in whom obstructive coronary artery disease is unlikely or, preferably, excluded by angiography. The advantages of noninvasive over invasive methodology are obvious. In particular, monitoring interventions that potentially modulate coronary microvascular dysfunction, which require serial measurements over longer periods of time, should benefit from a noninvasive approach. PET was proven to be the unrivalled imaging modality for absolute quantification of perfusion. The introduction of hybrid systems that combine PET with CT could be of additional benefit, as CT angiography could also exclude epicardial coronary artery disease in these patients. Perfusion quantification with CMR has rapidly evolved and, in the hands of few experienced centers, now offers an approach that combines absolute perfusion measurements with detailed functional, anatomical, and morphological cardiac information. MCE is the most accessible technique, and could theoretically be used in most research imaging centers. Technical limitations together with relatively inaccurate perfusion measurements and some safety concerns, however, have to date restricted widespread application of MCE.