Original studyCardioinhibitory response to carotid sinus massage in patients with coronary artery disease
References (11)
- et al.
Cardiac abnormalities associated with carotid-sinus syndrome
Lancet
(1965) - et al.
Carotid sinus hypersensitivity and the carotid sinus syndrome
Prog Cardiovasc Dis
(1989) - et al.
Carotid sinus hypersensitivity and syncope
Am J Cardiol
(1978) Activation of left ventricular receptors with nonmedullated vagal afferent fibers during occlusion of a coronary artery in the cat
Am J Cardiol
(1976)Hyperactive cardioinhibitory carotid sinus reflex: a possible aid in the diagnosis of coronary disease
Arch Intern Med
(1941)
Cited by (12)
Overlapped Stenting Is Associated with Postoperative Hypotension after Carotid Artery Stenting
2018, Journal of Stroke and Cerebrovascular DiseasesCitation Excerpt :High usage of cilostazol may also contribute to the low incidence of intraoperative BC, as well as to the unnecessity of additional treatments for intra- and postoperative BC. Previous studies have demonstrated the increased sensitivity of carotid artery baroreceptors in patients with coronary artery disease.34,35 Qureshi et al reported that increased baroreceptor sensitivity, in conjunction with a history of myocardial infarction, may have predisposed patients to postprocedural HT.9
Analysis of parameters associated with hypotension requiring vasopressor support after carotid angioplasty and stenting
2006, Journal of Vascular SurgeryCitation Excerpt :These patients, who required a short duration of vasopressors, had elevated rates of a history of myocardial infarction. This may be partly explained by data suggesting increased carotid artery baroreceptor sensitivity in patients with coronary artery disease.14,15 Previous studies have shown that patients with cardiac risk factors such as coronary artery disease,6 unstable angina,16 and previous myocardial infarction17 are more likely to have postprocedural hypotension after CAS.
Comparison of nonneurological events in high-risk patients treated by carotid angioplasty versus endarterectomy
2003, American Journal of SurgeryCitation Excerpt :The additional strain on the heart due to bradycardia and lower coronary perfusion pressure may have resulted in the adverse cardiac events in the CAS treatment group. It reported that patients with coronary artery disease have a heightened sensitivity of their carotid artery baroreceptors. [8]. This response occurs is proportion to the stretch experienced by the carotid artery baroreceptors.
Dysautonomic responses during percutaneous carotid intervention: Principles of physiology and management
2015, Catheterization and Cardiovascular InterventionsHemodynamic instability following carotid artery stenting
2011, Neurosurgical FocusAn evaluation of the incidence of haemodynamic depression during carotid angioplasty and stenting and its relationship with specific risk factors
2011, Wideochirurgia I Inne Techniki Maloinwazyjne