Elsevier

American Heart Journal

Volume 132, Issue 3, September 1996, Pages 516-527
American Heart Journal

Clinical investigation
Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque

https://doi.org/10.1016/S0002-8703(96)90233-1Get rights and content

Abstract

Currently, automated systems for quantitative analysis by intracoronary ultrasound (ICUS) are restricted to the detection of the lumen. The aim of this study was to determine the accuracy and reproducibility of a new semiautomated contour detection method, providing off-line identification of the intimal leading edge and external contour of the vessel in three-dimensional ICUS. The system allows cross-sectional and volumetric quantification of lumen and of plaque. It applies a minimum-cost algorithm and the concept that edge points derived from previously detected longitudinal contours guide and facilitate the contour detection in the cross-sectional images. A tubular phantom with segments of various luminal dimensions was examined in vitro during five catheter pull-backs (1 mm/sec), and subsequently 20 diseased human coronary arteries were studied in vivo with 2.9F 30 MHz mechanical ultrasound catheters (200 images per 20 mm segment). The ICUS measurements of phantom lumen area and volume revealed a high correlation with the true phantom areas and volumes (r = 0.99); relative mean differences were −0.65% to 3.86% for the areas and 0.25% to 1.72% for the volumes of the various segments. Intraobserver and interobserver comparisons showed high correlations (r = 0.95 to 0.98 for area and r = 0.99 for volume) and small mean relative differences (−0.87% to 1.08%), with SD of lumen, plaque, and total vessel measurements not exceeding 7.28%, 10.81%, and 4.44% (area) and 2.66%, 2.81%, and 0.67% (volume), respectively. Thus the proposed analysis system provided accurate measurements of phantom dimensions and can be used to perform highly reproducible area and volume measurements in three-dimensional ICUS in vivo.

References (39)

  • C von Birgelen et al.

    Volumetric intracoronary ultrasound: a new maximum confidence approach for the quantitative assessment of progression-regression of atherosclerosis?

    Atherosclerosis

    (1995)
  • CJ Slager et al.

    ANGUS: a new approach to three-dimensional reconstruction of geometry and orientation of coronary lumen and plaque by combined use of coronary angiography and IVUS

    J Am Coll Cardiol

    (1995)
  • PG Yock et al.

    Intravascular ultrasound: looking below the surface of vascular disease

    Circulation

    (1990)
  • SE Nissen et al.

    Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease

    Circulation

    (1991)
  • D Keane et al.

    Quantitative coronary angiography: an integral component of interventional cardiology

  • C Di Mario et al.

    Three-dimensional reconstruction of two-dimensional intracoronary ultrasound: clinical or research tool?

    Br Heart J

    (1995)
  • von Birgelen C, Kutryk MJB, Gil R, Ozaki Y, Di Mario C, Roelandt JRTC, et al. Quantification of the minimal luminal...
  • JRTC Roelandt et al.

    Three-dimensional reconstruction of intracoronary ultrasound images: rationale, approaches, problems, and directions

    Circulation

    (1994)
  • W Li et al.

    Semi-automatic contour detection for volumetric quantification of intracoronary ultrasound

  • Cited by (0)