Clinical trials with ambulatory blood pressure monitoring: fewer patients needed?

https://doi.org/10.1016/S0140-6736(94)90355-7Get rights and content

Abstract

Summary

We have tested the concept that fewer patients are needed in trials of antihypertensive treatment if blood pressure is measured by ambulatory monitoring rather than by conventional sphygmomanometry.

233 patients (≽60 years old) with isolated systolic hypertension were randomly allocated placebo (n=119) or active treatment (n=114). Blood pressure measurements were compared by Wilcoxon's test and blood pressure profiles by ANOVA. With either method of measurement, the same number of patients (40 in each treatment group) was required to show a reduction after 1 year in clinic (13/8 mm Hg) or average blood pressure over 24 h (9/5 mm Hg). To detect that the decrease in systolic pressure was not steadily maintained through the day, 40 patients in each treatment group were needed for blood pressure profiles made up of 4-hourly or 2-hourly means and 60 for profiles of 1-hourly means. For diastolic pressure, the corresponding numbers were 80, 100, and more than the number of available patients, respectively.

We conclude that parallel-group trials focusing on the average blood pressure over 24 h, rather than on conventionally measured blood pressure, cannot economise on sample size. Moreover, trials studying the full course of blood pressure throughout the day, require more—not fewer—patients than studies of only the conventional or average 24 h blood pressure.

References (30)

  • Wb White et al.

    National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers

    Hypertension

    (1993)
  • E. O'Brien et al.

    The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems

    J Ambul Monitoring

    (1991)
  • L. Thijs et al.

    Analysis of the diurnal blood pressure curve

    High Blood Press Cardiovasc Prev

    (1992)
  • Jwl Cole et al.

    Applications of multivariate analysis of variance to repeated measures experiments

    Biometrics

    (1966)
  • Cited by (52)

    • 24-Hour ambulatory blood pressure monitoring

      2006, American Heart Journal
      Citation Excerpt :

      Dose-ranging studies using ABPM can be conducted without a placebo arm and avoid ethical concerns about having one. However, between-subject variability, which is not related to intrasubject measurement imprecision, is the determinant of power calculations in parallel-group studies.62 Thus, the general view is that in trials of antihypertensive agents, using ABPM would not reduce sample size.

    • Pharmacotherapy for hypertension in adults 60 years or older

      2019, Cochrane Database of Systematic Reviews
    View all citing articles on Scopus
    View full text