Application of the proximal flow convergence method to calculate the effective regurgitant orifice area in aortic regurgitation

https://doi.org/10.1016/S0735-1097(98)00356-8Get rights and content
Under an Elsevier user license
open archive

Abstract

Objectives. We sought to determine the reliability of the proximal isovelocity surface area (PISA) method for calculation of effective regurgitant orifice (ERO) of aortic regurgitation (AR).

Background. The ERO area can be calculated by the PISA method, but this method has not been validated in AR.

Methods. ERO calculation by the PISA method was undertaken prospectively in 71 consecutive patients with isolated AR and achieved in 64 and compared with two simultaneous reference methods (quantitative Doppler and quantitative two-dimensional echocardiography). In addition, this method was compared with angiography in 12 patients, with surgical assessment in 18 patients and with ventricular volumes in all patients.

Results. Good correlations between PISA and reference methods were obtained (both r = 0.90, both p < 0.0001), but a trend toward underestimation of the ERO by the PISA method was noted (24 ± 19 vs. 26 ± 22 mm2and 27 ± 23 mm2, respectively, both p = 0.04). However, this trend was confined to five patients with an obtuse flow convergence angle (>220°), and on multivariate analysis this variable was the only independent determinant of underestimation of the ERO. In contrast, in 59 patients with a flat flow convergence (≤220°), the PISA method, in comparison with reference methods, showed excellent correlations, with a narrow standard error of the estimate (r = 0.95, SEE 5.4 mm2, and r = 0.95, SEE 5.8 mm2; all p < 0.0001) and no trend toward underestimation (22 ± 18 vs. 23 ± 16 mm2, p = 0.44, and vs. 23 ± 18 mm2, p = 0.34).

Conclusions. In patients with AR, the PISA method can be used to measure the ERO with reasonable feasibility. Underestimation of the ERO by PISA may occur in patients with an obtuse flow convergence angle. However, in most patients with appropriate flow convergence, PISA provides reliable measurement of the ERO of AR.

Abbreviations

AR
aortic regurgitation
ERO
effective regurgitant orifice
FC
flow convergence
PISA
proximal isovelocity surface area
SEE
standard error of the estimate