Abstract
Aims: Studies by intravascular ultrasound demonstrated inadequate expansion in a large number of stents, which lead to the increase of inflation pressures for stenting. The present study examined whether routine use of high-pressure inflation would be sufficient for an optimum stent expansion without sonographic guidance. Methods and results: Two types of single coronary stents (Palmaz-Schatz in 54, and Wiktor in 25) were implanted with inflation pressures of 16–20 atm in 79 nonocclusive coronary lesions. IVUS before stenting was used in 78% to select the adequate stent size. Intravascular ultrasound after stenting was used to assess the minimum stent area and diameter, the reference areas, and the strut apposition to the vessel wall. The difference between the area of the expanding balloon and the stent area was calculated as the luminal deficit of the stent. Completeness of stent expansion required full strut apposition and lesion coverage, and a minimum stent area that was larger than the distal reference, and larger than 60% of the proximal reference. Intravascular ultrasound before stenting lead to an increase of the stent size in 47%. After high-pressure expansion, even with the optimized balloon size, 8% of stents had struts protruding into the lumen. The stent area (6.87 ± 1.93 mm2) was significantly smaller than both the proximal (9.59 ± 2.91 mm2; p<0.001) and distal reference area (8.23 ± 3.03 mm2; p<0.001). The criteria for complete expansion were met in 48%. The expansion with a larger high-pressure balloon in 28 stents lead to an increase of the stent area by 19% (8.19 ± 2.24; p<0.001), and full stent apposition in all cases. The criteria of stent expansion were met in 82%. A wide range of the luminal deficit upto 48% was observed, which was not related to sonographic lesion characteristics, except in lesions with complete circumferential calcifications. The different stent designs were characterized by a slightly lower luminal deficit in slotted-tube stents (23 ± 13% vs. 28 ± 12%; p=0.11) and a better index of stent symmetry as compared with the coil stent (0.87 ± 0.08 vs. 0.82 ± 0.09; p<0.05). Conclusion: Routine use of high-pressure stent expansion did not lead to a sufficient stent expansion, even when the initial stent size had been guided by intravascular ultrasound. Further stent dilatation with larger balloons under ultrasound guidance would be required to optimize the luminal area gain.
Similar content being viewed by others
References
Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx G, Emanuelsson H, Marco J, Legrand V, Materne P, Belardi J, Sigwart U. Colombo A, Goy JJ, vd Heuvel P, Delcan J, Morel MA, Benestent Study Group. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994; 331: 489-495.
Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, Detre K, Veltri L, Ricci D, Nobuyoshi M, Cleman M, Heuser R, Almond D, Teirstein PS, Fish RD, Colombo A, Brinker J, Moses J, Shaknovich A, Hirshfeld J, Bailey S, Ellis S, Rake R, Goldberg S, Stent Restenosis Study Investigators. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med 1994; 331: 496-501.
Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, Gaglione A, Goldberg SL, Tobis JM. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 1995; 91: 1676-1688.
Morice MC, Zemour G, Benveniste E, Biron Y, Bourdonnec C, Faivre R, Fajadet J, Gaspard P, Glatt B, Joly P, et al. Intracoronary stenting without coumadin: one month results of a French multicenter study. Cathet Cardiovasc Diagn 1995; 35: 1-7.
Nakamura S, Colombo A, Gaglione A, Almagor Y, Goldberg SL, Maiello L, Finci L, Tobis JM. Intracoronary ultrasound observations during stent implantation. Circulation 1994; 89: 2026-2034.
Goldberg SL, Colombo A, Nakamura S, Almagor Y, Maiello L, Tobis JM. Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents. J Am Coll Cardiol 1994; 24: 996-1003.
Mudra H, Blasini R, Regar E, Klauss V, Rieber J, Theisen K. Intravascular ultrasound assessment of the balloon-expandable Palmaz-Schatz coronary stent. Coron Artery Dis 1993; 4: 791-799.
Gorge G, Haude M, Ge J, Voegele E, Gerber T, Rupprecht HJ, Meyer J, Erbel R. Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation. J Am Coll Cardiol 1995; 26: 725-730.
Schömig A, Neumann FJ, Kastrati A, Schühlen H, Blasini R, Hadamitzky M, Walter H, Zitzmann-Roth EM, Richardt G, Alt E, Schmitt C, Ulm K. A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary-artery stents. N Engl J Med 1996; 334: 1084-1089.
Morice MC, Commeau P, Monassier JP, Riou P, Lokuvard Y, Guerin Y, Jajadet J, Benveniste E, Cribier A, Bunout P. Coronary stenting without coumadine. Phase II, III, IV, V. Predictors of major complications. Eur Heart J 1995; 16(Abstract suppl.): 249.
Kuntz RE, Gibson CM, Nobuyoshi M, Baim DS. Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomy. J Am Coll Cardiol 1993; 21: 15-25.
Ellis SG, Savage M, Fischman D, Baim DS, Leon M, Goldberg S, Hirhfeld JW, Cleman MW, Teirstein PS, Walker C, Bailey S, Buchbinder M, Topol EJ, Schatz RA. Restenosis afterplacement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience. Circulation 1992; 86: 1836-1844.
Kimura T, Nosaka H, Yokoi H, Iwabuchi M, Nobuyoshi M. Serial angiographic follow-up after Palmaz-Schatz stent implantation: Comparison with conventional balloon angioplasty. J Am Coll Cardiol 1993; 21: 1557-1563.
Dussaillant GR, Mintz GS, Pichard AD, Kent KM, Satler LF, Popma JJ, Wong SC, Leon MB. Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis. J Am Coll Cardiol 1995; 26: 720-724.
Jaegere P de, Mudra H, Alamgor Y, Figulla H, Penn I, Doucet S, Bartorelli A, Hamm C, Music Study Investigators. In-hospital and 1-month clinical results of an international study testing the concept of IVUS guided optimized stent expansion alleviating the need of system anticoagulation. J Am Coll Cardiol 1996; 27(Suppl.A): 137 A.
Gerber TC, Erbel R, Gorge G, Ge J, Rupprecht HJ, Meyer J. Classification of morphologic effects of percutaneous trans-luminal coronary angioplasty assessed by intravascular ultrasound. Am J Cardiol 1992; 70: 1546-1554.
Hodgson JM, Reddy KG, Suneja R, Nair RN, Lesnefsky EJ, Sheehan HM. Intracoronary ultrasound imaging: correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty. J Am Coll Cardiol 1993; 21: 35-44.
Tobis JM, Mallery J, Mahon D, Lehmann K, Zalesky P, Griffith J, Gessert J, Moriuchi M, McRae M, Dwyer ML, Greep N, Henry WL. Intravascular ultrasound imaging of human coronary arteries invivo: analysis of tissue characterizations with comparison to in vitro histological specimens. Circulation 1991; 83: 319-326.
Werner GS, Sold G, Buchwald A, Kreuzer H, Wiegand V. Intravascular ultrasound imaging of human coronary arteries after percutaneous coronary angioplasty: morphologic and quantitative assessment. Am Heart J 1991; 122: 212-220.
Potkin BN, Keren G, Mintz GS, Douek PC, Pichard AD, Satler LF, Kent KM, Leon MB. Arterial responses to balloon coronary angioplasty: an intravascular ultrasound study. J Am Coll Cardiol 1992; 20: 942-951.
Honye J, Mahon DJ, Jain A, White CJ, Ramee SR, Wallis JB, Al-Zarka A, Tobis JM. Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging. Circulation 1992; 85: 1012-1025.
Rechavia E, Litvack F, Macko G, Eigler NL. Influence of expanded balloon diameter on Palmaz-Schatz stent recoil. Cathet Cardiovasc Diagn 1995; 36: 11.
Mintz GS, Popma JJ, Pichard AD, Kent KM, Satler LF, Chuang YC, Ditrano CJ, Leon MB. Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions. Circulation 1995; 91: 1959-1965.
Serruys PW, Di-Mario C. Who was thrombogenic: the stent or the doctor? [editorial] Circulation 1995; 91: 1891-1893.
Buchwald AB, Möller K, Werner GS, Unterberg C. Optimal coronary implantation of Wiktor stents: over sizing versus high-pressure dilatation (abstract).Eur Heart J 1996; 17(Abstract suppl.): 172.
Mintz GS, Painter JA, Pichard AD, Kent KM, Satler LF, Popma JJ, Chuang YC, Bucher TA, Sokolowicz LE, Leon MB. Atherosclerosis in angiographically ‘normal’ coronary artery reference segments: an intravascular ultrasound study with clinical correlations. J Am Coll Cardiol. 1995; 25: 1479-1485.
Stone GW, St. Goar FG, Linnemeier T, Sheehan H, Hodgson JmcB. Variability in balloon sizing during routine PTCA — quantitative coronary and ultrasound analysis. J Am Coll Cardiol 1996; 27(Suppl.A): 361A.
Hausmann D, Erbel R, Alibelli-Chemarin MJ, Boksch W, Caracciolo E, Cohn JM, Culp SC, Daniel WG, DeScheerder I, DiMario C, Ferguson JJ III, Fitzgerald PJ, Friedrich G, Ge J, Görge G, Hanrath P, Hodgson JM, Isner JM, Jain S, Maier-Rudolph W, Mooney M, Moses JW, Mudra H, Pinto FJ, Smalling RW, Talley D, Tobis JM, Walter PD, Weidinger F, Werner GS, Yeung AC, Yock PG. The safety of intracoronary ultrasound: A multicenter survey of 2207 examinations. Circulation 1995; 91: 623-630.
Sharma SK, Israel DH, Kamean JL, Bodian CA, Ambrose JA. Clinical, angiographic, and procedural determinants of major and minor coronary dissection during angioplasty. Am Heart J 1993; 126: 39-47.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Werner, G.S., Diedrich, J., Schünemann, S. et al. Additional luminal area gain by intravascular ultrasound guidance after coronary stent implantation with high inflation pressure. Int J Cardiovasc Imaging 13, 311–321 (1997). https://doi.org/10.1023/A:1005703626872
Issue Date:
DOI: https://doi.org/10.1023/A:1005703626872