Skip to main content
Log in

Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique

  • Published:
The International Journal of Cardiac Imaging Aims and scope Submit manuscript

Abstract

Three-dimensional (3D) echocardiography may overcome the problems with inadequate accuracy and reproducibility of 2D volume measurements of the left ventricle. Aims: To establish the in vitro accuracy and reproducibility of two new methods for 3D echocardiographic volume determination as compared to biplane measurements. Methods: Validation of volume measurements by a multiplane 3D method was performed on asymmetric latex phantoms (n=8, true volumes 45-304 ml) using rotational acquisition of 90 image planes. Porcine agarose-filled asymmetrical left ventricles (n=7, true volumes 34 – 280 ml) were measured by the same multiplane 3D method based on images acquired by probe rotation axis perpendicular (A) and parallel (B) to the ventricular long axis. Ventricular volumes were also obtained by a simplified 3D system using only the three standard apical views (C) and by the ordinary biplane Simpson’s method (D). Results: On latex phantoms systematic deviation from true volumes by multiplane 3D was less than 2%, and 95% variability of individual measurements from this mean was ± 4,9%. For accuracy on left ventricles, systematic bias was small with all the methods (<5%), but 95% variability of individual measurements was ±9,0%, 15.4%, 18.8% and 41.3% of true volumes for methods A-D respectively. Corresponding results in the same range were obtained for inter- and intraobserver variability. Conclusion: Individual in vitro volume estimates of left ventricles are of similar quality using apical multiplane or apical triplane 3D echocardiography. Both methods were superior to the ordinary apical biplane method, but inferior to multiplane 3D method with the probe directed perpendicular to the ventricular long axis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Schiller NB, Shah PM, Crawford M, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989; 2: 358–67.

    Google Scholar 

  2. Pandian NG, Roeland J, Nanda NC, et al. Dynamic Three-Dimensional Echocardiography: Methods and Clinical Potential. Echocardiography 1994; 11: 237–59.

    Google Scholar 

  3. Pearlman AS. Measurement of left ventricular volume by three-dimensional echocardiography-present promise and potential problems. J Am Coll Cardiol 1993; 22: 1538–40.

    Google Scholar 

  4. Roelandt JR. Three-dimensional echocardiography: new views from old windows [editorial]. Br Heart J1995; 74: 4–6.

    Google Scholar 

  5. Maehle J. Assessment of Left Ventricular Volume and Regional Dysfuction Based on 3D Endocardial Surfaces Reconstructed from 2D Ultrasond Images of the Heart. NTNU Report, Trondheim, Norway 1996; F, 1–16.

    Google Scholar 

  6. Maehle J, Aakhus S, Bjoernstad K, Torp H. How many apical echoccardiographic views should be used to determine left ventricular dimensions and shape from three-dimensional reconstruction of endocardial surfaces? European Heart Journal 1996; 17: 44 (Abstract)

    Google Scholar 

  7. Roelandt JR, ten Cate FJ, Vletter WB, Taams MA. Ultrasonic dynamic three-dimensional visualization of the heart with a multiplane transesophageal imaging transducer. J Am Soc Echocardiogr 1994; 7: 217–29.

    Google Scholar 

  8. Salustri A, Spitaels S, McGhie J, Vletter W, Roelandt JR. Transthoracic three-dimensional echocardiography in adult patients with congenital heart disease. J Am Coll Cardiol 1995; 26: 759–67.

    Google Scholar 

  9. Salustri A, Roelandt J. Three dimensional reconstruction of the heart with rotational acquisition: methods and clinical applications. Br Heart J 1995; 73(Suppl 2): 10–5.

    Google Scholar 

  10. Aakhus S, Maehle J, Bjoernstad K. A new method for echocardiographic computerized three-dimensional reconstruction of left ventricular endocardial surface: in vitro accuracy and clinical repeatability of volumes. J Am Soc Echocardiogr 1994; 7: 571–81.

    Google Scholar 

  11. Maehle J, Bjoernstad K, Aakhus S, Torp HG, Angelsen BAJ. Three-Dimensional Echocardiography for Quantitative Left Ventricular Wall Motion Analyses. Echocardiography 1994; 11: 397–408.

    Google Scholar 

  12. King DL, Gopal AS, Keller AM, Sapin PM, Schroder KM. Three-dimensional echocardiography. Advances for measurement of ventricular volume and mass. Hypertension 1994; 23: 172–9.

    Google Scholar 

  13. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307–10.

    Google Scholar 

  14. Keene ON. The log transformation is special. Stat Med 1995; 14: 811–9.

    Google Scholar 

  15. Henry WL, DeMaria A, Feigenbaum H, et al. Report of The American Society of Echocardiography Committee on Nomenclature and Standards: Identification of Myocardial Wall Segments. 1982; (Report)

  16. Gopal AS, King DL, Katz J, Boxt LM, King DL, Jr., Shao MY. Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imaging. J Am Soc Echocardiogr 1992; 5: 115–24.

    Google Scholar 

  17. Handschumacher MD, Lethor JP, Siu SC, et al. A new integrated system for three-dimensional echocardiographic reconstruction: development and validation for ventricular volume with application in human subjects. J Am Coll Cardiol 1993; 21: 743–53.

    Google Scholar 

  18. Schroder KM, Sapin PM, King DL, Smith MD, DeMaria AN. Three-dimensional echocardiographic volume computation: in vitrocomparison to standard two-dimensional echocardiography. J Am Soc Echocardiogr1993; 6: 467–75.

    Google Scholar 

  19. Sapin PM, Schroeder KD, Smith MD, DeMaria AN, King DL. Three-dimensional echocardiographic measurement of left ventricular volume in vitro: comparison with two-dimensional echocardiography and cineventriculography. J Am Coll Cardiol 1993; 22: 1530–7.

    Google Scholar 

  20. Siu SC, Levine RA, Rivera JM, et al. Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performance. Am Heart J 1995; 130: 812–22.

    Google Scholar 

  21. Mele J, Mæchie J, Pratola C, Pedini I, Alboni P, Levine RA. A new simplified system for three-dimensional echo reconstructions of the left ventricle. Application in normal subjects and ischemic patients. Eur Heart J 1995; 16: 206 (Abstract)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rodevand, O., Bjornerheim, R., Aakhus, S. et al. Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique. Int J Cardiovasc Imaging 14, 55–63 (1998). https://doi.org/10.1023/A:1005820303511

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1005820303511

Navigation