2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis

J Am Coll Cardiol. 2011 Apr 19;57(16):1650-7. doi: 10.1016/j.jacc.2010.11.044.

Abstract

Objectives: The purpose of this study was to evaluate the safety, device performance, and clinical outcome up to 2 years for patients undergoing transcatheter aortic valve implantation (TAVI).

Background: The role of TAVI in the treatment of calcific aortic stenosis evolves rapidly, but mid- and long-term results are scarce.

Methods: We conducted a prospective, multicenter, single-arm study with symptomatic patients undergoing TAVI for treatment of severe aortic valve stenosis using the 18-F Medtronic CoreValve (Medtronic, Minneapolis, Minnesota) prosthesis.

Results: In all, 126 patients (mean age 82 years, 42.9% male, mean logistic European System for Cardiac Operative Risk Evaluation score 23.4%) with severe aortic valve stenosis (mean gradient 46.8 mm Hg) underwent the TAVI procedure. Access was transfemoral in all but 2 cases with subclavian access. Retrospective risk stratification classified 54 patients as moderate surgical risk, 51 patients as high-risk operable, and 21 patients as high-risk inoperable. The overall technical success rate was 83.1%. Thirty-day all-cause mortality was 15.2%, without significant differences in the subgroups. At 2 years, all-cause mortality was 38.1%, with a significant difference between the moderate-risk group and the combined high-risk groups (27.8% vs. 45.8%, p = 0.04). This difference was mainly attributable to an increased risk of noncardiac mortality among patients constituting the high-risk groups. Hemodynamic results remained unchanged during follow-up (mean gradient: 8.5 ± 2.5 mm Hg at 30 days and 9.0 ± 3.4 mm Hg at 2 years). Functional class improved in 80% of patients and remained stable over time. There was no incidence of structural valve deterioration.

Conclusions: The TAVI procedure provides sustained clinical and hemodynamic benefits for as long as 2 years for patients with symptomatic severe aortic stenosis at increased risk for surgery.

Publication types

  • Comparative Study
  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / pathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Female
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / methods
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Prospective Studies
  • Prosthesis Design / instrumentation*
  • Prosthesis Design / methods
  • Time Factors
  • Treatment Outcome