Comparison of outcome after valve replacement with a bioprosthesis versus a mechanical prosthesis: initial 5 year results of a randomized trial

J Am Coll Cardiol. 1987 Oct;10(4):719-32. doi: 10.1016/s0735-1097(87)80263-2.

Abstract

The Veterans Administration Cooperative Study on Valvular Heart Disease was organized to compare survival and incidence of valve-related complications between patients receiving a bioprosthesis (the Hancock porcine heterograft) and a mechanical prosthesis (the Björk-Shiley spherical disc valve). Five hundred seventy-five patients undergoing single aortic or mitral valve replacement were randomized at surgery to one of the two valve types. At an average follow-up of 5 years (range 3 to 8) there are no statistically significant differences in survival between patients with the two valve types in the aortic valve replacement group. There is a statistically nonsignificant trend toward improved survival in patients undergoing mitral valve replacement with a bioprosthesis compared with a mechanical prosthesis (5 year survival probability was 0.70 +/- 0.05 and 0.58 +/- 0.06, respectively). Fatal and nonfatal valve-related complications occurred significantly less frequently in patients with a bioprosthesis compared with a mechanical prosthesis for both mitral and aortic valve replacement. Five year complication-free probability was 0.67 +/- 0.05 and 0.45 +/- 0.06, respectively, for patients with mitral valve replacement and 0.63 +/- 0.04 and 0.53 +/- 0.04, respectively, for those with aortic valve replacement. The difference in overall complication rates was largely due to the increased number of clinically significant but nonfatal bleeding episodes in patients receiving a mechanical prosthesis. Adjustment for differences in baseline characteristics between patients receiving a mitral mechanical prosthesis and a mitral bioprosthesis reduced the statistical significance of the difference in both mortality and complications.

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Aortic Valve / surgery
  • Bioprosthesis / adverse effects
  • Bioprosthesis / mortality*
  • Clinical Trials as Topic
  • Follow-Up Studies
  • Heart Valve Prosthesis / adverse effects
  • Heart Valve Prosthesis / mortality*
  • Hemorrhage / etiology
  • Humans
  • Male
  • Middle Aged
  • Mitral Valve / surgery
  • Prosthesis Design
  • Random Allocation
  • Reoperation
  • Thromboembolism / etiology