Fluid mechanics of a model mitral valve and left ventricle

BJ Bellhouse - Cardiovascular research, 1972 - academic.oup.com
AUTHOR'S SYNOPSIS A model of the left ventricle was built incorporating a mitral and an
aortic valve. The bicuspid mitral valve was seen to achieve most of its closure during …

Transdermal and transmucosal powdered drug delivery

TL Burkoth, BJ Bellhouse, G Hewson… - Critical Reviews™ in …, 1999 - dl.begellhouse.com
High-velocity powder injection is a promising new drag-delivery technique that provides
needle-and pain-free delivery of traditional drags, drags from biotechnology such as …

The fluid mechanics of the aortic valve

BJ Bellhouse, L Talbot - Journal of fluid mechanics, 1969 - cambridge.org
The closure mechanism of the human aortic valve is investigated experimentally with a rigid-
walled model placed in a pulsatile water-tunnel. It is shown that the valve is controlled by a …

Mechanism of closure of the aortic valve

BJ Bellhouse, FH Bellhouse - Nature, 1968 - nature.com
THE human aortic valve consists of three cusps made of relatively inelastic, muscle-free
material about 0.15 mm thick. It opens and shuts about once a second, and withstands a …

Determination of mean and dynamic skin friction, separation and transition in low-speed flow with a thin-film heated element

BJ Bellhouse, DL Schultz - Journal of Fluid Mechanics, 1966 - cambridge.org
The application of a heated thin metallic film to the measurement of mean skin friction in
laminar and turbulent flow on a flat plate, circular cylinder and in an annular tunnel is …

A high efficiency membrane oxygenator and pulsatile pumping system, and its application to animal trials

BJ Bellhouse, FH Bellhouse, CM Curl… - ASAIO …, 1973 - journals.lww.com
METHODS Three series of experiments were undertaken. In the first, partial veno-venous
bypass in adult pigs was undertaken using one catheter through the external jugular vein …

On flow through furrowed channels. Part 2. Observed flow patterns

KD Stephanoff, IJ Sobey, BJ Bellhouse - Journal of Fluid Mechanics, 1980 - cambridge.org
Observations of flow in furrowed channels support the calculations of part 1 (Sobey 1980). If
the mainstream flow is steady there is a critical Reynolds number below which separation …

Fluid mechanics of the aortic root with application to coronary flow

BJ Bellhouse, FH Bellhouse, KG Reid - Nature, 1968 - nature.com
ANATOMICAL studies have demonstrated the lateral extent of the sinus of Valsalva which
has a well defined ridge forming its upper margin, and have indicated that the geometry of …

Flow in branching vessels

R Brech, BJ Bellhouse - Cardiovascular Research, 1973 - academic.oup.com
Flow in branching vessels’ Page 1 Cardiovascular Research, 1973, 7, 593-600. Flow in
branching vessels’ R. BRECH and B. J. BELLHOUSE From the Department of Engineering …

Investigations of gas and particle dynamics in first generation needle-free drug delivery devices

NJ Quinlan, MAF Kendall, BJ Bellhouse, RW Ainsworth - Shock waves, 2001 - Springer
Transdermal powdered drug delivery involves the propulsion of solid drug particles into the
skin by means of high-speed gas-particle flow. The fluid dynamics of this technology have …