User profiles for "author:Niti Dhutia"

Niti Dhutia

Imperial College London
Verified email at ic.ac.uk
Cited by 397

[HTML][HTML] Defining the real-world reproducibility of visual grading of left ventricular function and visual estimation of left ventricular ejection fraction: impact of image …

GD Cole, NM Dhutia, MJ Shun-Shin, K Willson… - The international journal …, 2015 - Springer
Left ventricular function can be evaluated by qualitative grading and by eyeball estimation of
ejection fraction (EF). We sought to define the reproducibility of these techniques, and how …

Test–retest repeatability of cardiopulmonary exercise test variables in patients with cardiac or respiratory disease

A Barron, N Dhutia, J Mayet, AD Hughes… - European journal of …, 2014 - academic.oup.com
Background The test–retest reliability for multiple cardiopulmonary exercise test (CPX)
variables has not been compared in a single study and the influence of different diseases on …

Automated multi-beat tissue Doppler echocardiography analysis using deep neural networks

ES Lane, J Jevsikov, MJ Shun-Shin, N Dhutia… - Medical & Biological …, 2023 - Springer
Tissue Doppler imaging is an essential echocardiographic technique for the non-invasive
assessment of myocardial blood velocity. Image acquisition and interpretation are performed …

Aortic reservoir pressure corresponds to cyclic changes in aortic volume: physiological validation in humans

MG Schultz, JE Davies, A Hardikar, S Pitt… - … , and vascular biology, 2014 - Am Heart Assoc
Objective—Aortic reservoir pressure indices independently predict cardiovascular events
and mortality. Despite this, there has never been a study in humans to determine whether …

Automatic detection of end‐diastolic and end‐systolic frames in 2D echocardiography

M Zolgharni, M Negoita, NM Dhutia… - …, 2017 - Wiley Online Library
Background Correctly selecting the end‐diastolic and end‐systolic frames on a 2D
echocardiogram is important and challenging, for both human experts and automated …

Automated aortic Doppler flow tracing for reproducible research and clinical measurements

M Zolgharni, NM Dhutia, GD Cole… - IEEE transactions on …, 2014 - ieeexplore.ieee.org
In clinical practice, echocardiographers are often unkeen to make the significant time
investment to make additional multiple measurements of Doppler velocity. Main hurdle to …

Doppler assessment of aortic stenosis: a 25-operator study demonstrating why reading the peak velocity is superior to velocity time integral

S Sacchi, NM Dhutia, MJ Shun-Shin… - European Heart …, 2018 - academic.oup.com
Aims Measurements with superior reproducibility are useful clinically and research
purposes. Previous reproducibility studies of Doppler assessment of aortic stenosis (AS) …

Guidance for accurate and consistent tissue Doppler velocity measurement: comparison of echocardiographic methods using a simple vendor-independent method …

NM Dhutia, M Zolgharni, K Willson… - European Heart …, 2014 - academic.oup.com
Background Variability has been described between different echo machines and different
modalities when measuring tissue velocities. We assessed the consistency of tissue velocity …

[HTML][HTML] Open-source, vendor-independent, automated multi-beat tissue Doppler echocardiography analysis

NM Dhutia, M Zolgharni, M Mielewczik… - The international journal …, 2017 - Springer
Current guidelines for measuring cardiac function by tissue Doppler recommend using
multiple beats, but this has a time cost for human operators. We present an open-source …

[HTML][HTML] Physiology of oxygen uptake kinetics: Insights from incremental cardiopulmonary exercise testing in the Study of Health in Pomerania

AJ Barron, NM Dhutia, S Gläser, B Koch, R Ewert… - IJC Metabolic & …, 2015 - Elsevier
Background Cardiopulmonary exercise testing allows for assessment of cardiac and
respiratory limitation, but is often affected by patient effort. Indices of oxygen kinetics …