Regional variation in ICD implantation rates: the shocking truth?
  1. C C Lang
  1. Correspondence to:
    Dr Christopher C Lang
    Department of Cardiology, Royal Infirmary of Edinburgh, Little France Crescent, Edinburgh EH16 4SA, UK; chrislangkatamail.com

Abstract

There is considerable disparity in the implantation of ICDs across the UK, with a fourfold difference between regions with the highest and lowest implantation rates

  • AVID, antiarrhythmics versus implantable defibrillators
  • CIDS, Canadian implantable defibrillator study
  • EP, electrophysiology
  • ICD, implantable cardioverter-defibrillator
  • MADIT, multicentre automatic defibrillator implantation trial
  • MUSTT, multicenter unsustained tachycardia trial
  • NICE, National Institute for Clinical Excellence
  • OOHCA, out of hospital cardiac arrest
  • defibrillator
  • ICD
  • ICD implantation rate
  • implantable cardioverter-defibrillator
  • UK

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

In this issue of Heart, Cunningham et al1 present audit data from the National Pacemaker Database for the period 1998–2002 detailing the implantation rates of implantable cardioverter-defibrillators (ICDs) and show that the UK as a whole is implanting fewer ICDs than many western European countries. This article represents an update on previous reports with similar findings.2,3 In addition to these national comparisons, the authors break down implantation rates by region and demonstrate considerable disparity, with a fourfold difference between regions with the highest and lowest rate of ICD implantation.

Since the introduction of ICDs into clinical practice, considerable evidence from controlled randomised trials has been produced supporting their use in both secondary and primary prevention settings. In particular, the utility of ICDs has been shown in patients with ischaemic heart disease and left ventricular impairment, who represent the majority of patients suffering sudden cardiac death. Guidelines for England and Wales were produced in 2000 by the National Institute for Clinical Excellence (NICE) based on the trial data available at that time, stipulating criteria that should be fulfilled for a patient to receive a device.4 This document suggested that an implantation rate of around 50 per million population per year could be expected.

The data presented by Cunningham spans a transitional period in terms of clinical practice, including the publication of the NICE guidelines. As expected, over the study period there was a rise in implantation rates in all four countries of the UK. Northern Ireland was the only country to achieve the implant rate predicted by NICE of 50 per million per year. The range of implantation rates seen within the regional “league table” in Cunningham’s article requires further investigation and scrutiny. The observed differences are unlikely to be explained by physician’s attitudes to, or execution of, the NICE guidelines.

PRIMARY VERSUS SECONDARY PREVENTION?

Until relatively recently, ICDs were largely reserved for patients surviving an out of hospital cardiac arrest (OOHCA), or having had life threatening arrhythmias while on amiodarone treatment. Subsequently, study data demonstrated the superiority of ICDs compared to antiarrhythmic treatment, particularly when left ventricular function is impaired (the AVID5 and CIDS6 trials), encouraging us to consider device therapy as the first choice in these patients. The MADIT7 and MUSTT8 trials provided support for the use of ICDs for the primary prevention of sudden death in patients with ischaemic heart disease and impaired left ventricular function found to have inducible ventricular arrhythmias at electrophysiological (EP) testing. Based on MADIT data, the NICE guidelines stipulated that patients with previous myocardial infarction, a non-sustained ventricular tachycardia on Holter, and an ejection fraction of less than 35% should be considered for an ICD if sustained ventricular tachycardia can be induced during EP testing. These criteria defined the national therapeutic indications for ICD, and a rise in implantation rates was expected. The observed increase in implantation rates has been slow, with considerable variation across the UK. Several factors need to be considered in order to understand the observed variation.

SECONDARY PREVENTION

Patients with life threatening arrhythmias and ischaemic heart disease account for around 75% of all individuals with a secondary prevention indication for ICD therapy. Cunningham et al1 state that the regional variation in implantation rate cannot be explained by differences in survival from cardiac arrest. However, there is evidence that the likelihood of surviving OOHCA does indeed vary widely, and is dependent on local factors such as the distance from the arrest location to the nearest ambulance station. For example, the probability of survival to hospital admission varies more than fourfold between the hinterland of Edinburgh and the city centre,9 with the distance between arrest location and ambulance station being a key factor; this suggests that less densely populated regions would have a significantly lower OOHCA survival rate than regions where the population is predominantly city based. In addition, comparisons between data from North Glasgow and Edinburgh from a similar period in time show at least a fourfold variation in survival to discharge rates.9,10

PRIMARY PREVENTION

By and large, patients with a secondary prevention indication are readily identifiable. However, patients with primary prevention indications (as defined by NICE) are harder to recognise. To identify “at risk” patients there must be a comprehensive screening programme of patients with previous myocardial infarction which includes not only the assessment of left ventricular function (which should ideally be done more than one month from the time of the infarct), but also the presence of non-sustained ventricular tachycardia on Holter monitoring. Patients fulfilling these criteria then have to be referred for invasive EP testing. The identification of these patients requires a change in practice for the follow up of patients, and EP testing will in most cases require referral or transfer to a tertiary centre. The selection criteria therefore decrease the probability of identification through their complexity and the resource implications.

Patients identified and referred for ICD implantation for primary prevention represent the tip of the iceberg in terms of the number that would actually benefit from such therapy, and an implantation rate of 50 per million is a conservative estimate.11 That some regions are only reaching a fifth of this rate suggests problems identifying these patents. Cardiology departments need to consider integrating screening for arrhythmic risk into post-myocardial infarction follow up and heart failure clinics in order to increase detection rates.

The trends in the relative proportion of primary and secondary prevention ICD recipients would be helpful to understand whether the NICE guidelines were being embraced and successfully implemented, both nationally and regionally. One might expect that the increase in implantation rate would be largely accounted for by an increase in primary prevention implants, as a dramatic increase in survival following OOHCA is not likely to occur without major changes in the delivery of out of hospital resuscitation care.

RESOURCE IMPLICATIONS: MORE CENTRES OR BIGGER CENTRES?

There has been a dramatic increase in the number of consultant cardiologists in England due to additional funding for the management of cardiac disease through the National Service Framework. This will have had a positive impact on the management of patients with ischaemic heart disease and possibly in the identification and management of patients at risk of arrhythmias. The variations in national and regional implantation data may reflect the distribution of cardiologists. It would be useful to correlate the implantation rates with the distribution of electrophysiologists or device specialists. Running a comprehensive ICD service is costly and staff intensive, and an increase in implantation rates can only be achieved through the provision of adequate resources in terms of screening patients, device costs, and technical support for follow up.

There is no practical reason why in principle, as with bradycardia pacing, ICD implantation should be confined to tertiary centres. Technically, implanting a modern defibrillator requires little additional experience to that already possessed by a cardiologist who performs pacing. Devices are now small enough that the implantation technique is virtually identical to that of a bradycardia pacemaker. VF induction and defibrillation is performed under conscious sedation rather than general anaesthesia, and the precautions necessary to perform this safely are the same as when sedation is employed for transoesophageal echocardiography. Although initial programming and follow up of these devices requires training and careful thought, device companies run frequent excellent courses to support physicians and technicians in this area.

DATA COLLECTION AND MONITORING

For many years, we have been collecting data on coronary angiography and intervention using the Minerva database. This database provides data on patient demographics, risk factors, indications, complications, and outcomes. At present, there is no such system in place for pacemakers and defibrillators. The data collected by the National Pacemaker Database is invaluable, as the article by Cunningham et al1 demonstrates. It would be extremely useful to extend the scope of data collection for ICDs to include primary and secondary prevention indications, and more detail on patient characteristics, as is the case with coronary intervention. In addition, as recommended by NICE, all cardiology units must audit their practice in order to estimate demand and take steps to secure resources. It will also be important to collect data on the incidence of patients fulfilling the criteria used in the later primary prevention trials such as MADIT-II12 and SCD-HeFT,13 as the outcomes of these studies will influence future guidelines and it will be advantageous to appreciate in advance the implications for service provision.

THE FUTURE?

NICE is due to issue new guidance on ICD therapy in coming months. It is likely that the results of the more recent secondary prevention study MADIT-II will influence selection criteria, which would simplify the identification of patients by removing the need for EP testing, but at the same time increasing the number of eligible patients.

It is essential that we acknowledge regional trends in ICD implantation and seek explanations for the observations. The data presented by Cunningham et al1 is now more than two years out of date, and more frequent data collection and reporting is necessary to keep abreast of the situation. Managed clinical networks will facilitate regional service provision, helping to resolve issues and assist in service expansion. As with interventional cardiology, an expansion in the number of “device specialists” will be necessary, and not only in major teaching hospitals. Hopefully, the article by Cunningham et al will provide the stimulus for change in this important area.